CVE-2014-9188 | Schneider Electric ProClima Command Injection

Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.

Published: 2014-12-27 Last update: 2026-05-06 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2014-9188 is rated High Risk (75/100): CVSS Critical severity, with high exploitation likelihood (EPSS 19.57%, 95th percentile). Core evidence: EPSS ranks this CVE among the most likely to be exploited in the near term. EPSS rose +1.63% over the last day, indicating growing attacker interest. Mandatory action: High exploitation likelihood—assess exposure and prioritize remediation.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2014-9188

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-01-15 17.94% 19.57% +1.63%
2 2025-12-21 9.12% 17.94% +8.83%
3 2025-07-26 9.12%

Full EPSS history (21 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2014-9188

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
10.0 2.0 HIGH
AV:N/AC:L/Au:N/C:C/I:C/A:C Click to expand
Access vector (AV:N)
Can be exploited remotely over network reachability.
Access complexity (AC:L)
Exploitation conditions are straightforward and predictable.
Authentication (AU:N)
No authentication is required.
Confidentiality impact (C:C)
Complete confidentiality impact.
Integrity impact (I:C)
Complete integrity impact.
Availability impact (A:C)
Complete availability impact.
10.0 10.0 [email protected]
9.0 2.0 HIGH
AV:N/AC:L/Au:N/C:C/I:P/A:P Click to expand
Access vector (AV:N)
Can be exploited remotely over network reachability.
Access complexity (AC:L)
Exploitation conditions are straightforward and predictable.
Authentication (AU:N)
No authentication is required.
Confidentiality impact (C:C)
Complete confidentiality impact.
Integrity impact (I:P)
Partial integrity impact.
Availability impact (A:P)
Partial availability impact.
10.0 8.5 [email protected]

Weakness enumeration for CVE-2014-9188

Affected software / configurations for CVE-2014-9188

Vendor Product Version Raw CPE
schneider_electric proclima <= 6.0.1 cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:*

References for CVE-2014-9188

cvelogic Threat Intelligence