A vulnerability has been identified in Simcenter Femap V2406 (All versions < V2406.0003), Simcenter Femap V2412 (All versions < V2412.0002). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted STP file. This could allow an attacker to execute code in the context of the current process.(ZDI-CAN-26692)
Conclusion & alert: CVE-2025-40762 is rated Low Risk (36.6/100): CVSS High severity, with low exploitation likelihood (EPSS 0.07%). Mandatory action: Monitor for updates and reassess as exploit intelligence or EPSS changes.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-08 | 0.01% | 0.07% | +0.05% |
| 2 | 2025-08-12 | — | 0.01% | — |
Full EPSS history (2 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 7.3 | 4.0 | HIGH |
|
— | — | [email protected] |
| 7.8 | 3.1 | HIGH |
|
1.8 | 5.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| siemens | simcenter_femap | >= 2406.0000, < 2406.0003 | cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:* |
| siemens | simcenter_femap | >= 2412.0000, < 2412.0002 | cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:* |
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-674084.html | Vendor Advisory |