CVE-2017-10719

Exp

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has default Wi-Fi credentials that are exactly the same for every device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries.

Published: 2019-06-17 Last update: 2024-11-21 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2017-10719 is rated High Exploit Risk (68.4/100): CVSS Medium severity, with medium exploitation likelihood (EPSS 1.12%). Core evidence: 1 public exploit reference(s) are indexed (Exploit-DB). Mandatory action: Public exploits are available—assess exposure, apply mitigations, and prioritize patching.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Public exploit references (Exploit-DB) for CVE-2017-10719

EDB-ID Source Kind Published Link
nvd_ref exploit_tag Exploit-DB ↗

Exploit prediction scoring system (EPSS) score for CVE-2017-10719

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-05-18 1.16% 1.12% -0.04%
2 2026-04-03 0.45% 1.16% +0.71%
3 2025-03-30 0.45%

Full EPSS history (16 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2017-10719

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
6.5 3.0 MEDIUM
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:L)
A normal user session is enough; they don’t have to be admin.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:N)
Data isn’t meaningfully altered or forged.
Availability (A:N)
Service keeps running; no real outage angle.
2.8 3.6 [email protected]
4.0 2.0 MEDIUM
AV:N/AC:L/Au:S/C:P/I:N/A:N Click to expand
Access vector (AV:N)
Can be exploited remotely over network reachability.
Access complexity (AC:L)
Exploitation conditions are straightforward and predictable.
Authentication (AU:S)
A single authentication is required.
Confidentiality impact (C:P)
Partial confidentiality impact.
Integrity impact (I:N)
No integrity impact.
Availability impact (A:N)
No availability impact.
8.0 2.9 [email protected]

Weakness enumeration for CVE-2017-10719

Affected software / configurations for CVE-2017-10719

Vendor Product Version Raw CPE
ishekar endoscope_camera_firmware cpe:2.3:o:ishekar:endoscope_camera_firmware:*:*:*:*:*:*:*:*

References for CVE-2017-10719

cvelogic Threat Intelligence