CVE-2017-11579

Exp

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.

Published: 2019-07-02 Last update: 2024-11-21 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2017-11579 is rated High Exploit Risk (67.9/100): CVSS High severity, with medium exploitation likelihood (EPSS 0.62%). Core evidence: 1 public exploit reference(s) are indexed (Exploit-DB). Mandatory action: Public exploits are available—assess exposure, apply mitigations, and prioritize patching.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Public exploit references (Exploit-DB) for CVE-2017-11579

EDB-ID Source Kind Published Link
nvd_ref exploit_tag Exploit-DB ↗

Exploit prediction scoring system (EPSS) score for CVE-2017-11579

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-06-02 0.74% 0.62% -0.12%
2 2026-04-17 0.76% 0.74% -0.01%
3 2025-03-30 0.76%

Full EPSS history (10 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2017-11579

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
7.1 3.0 HIGH
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:L)
Attackers could change some data, but it’s limited—not everything goes.
Availability (A:N)
Service keeps running; no real outage angle.
2.8 4.2 [email protected]
4.8 2.0 MEDIUM
AV:A/AC:L/Au:N/C:P/I:P/A:N Click to expand
Access vector (AV:A)
Requires access to an adjacent network segment.
Access complexity (AC:L)
Exploitation conditions are straightforward and predictable.
Authentication (AU:N)
No authentication is required.
Confidentiality impact (C:P)
Partial confidentiality impact.
Integrity impact (I:P)
Partial integrity impact.
Availability impact (A:N)
No availability impact.
6.5 4.9 [email protected]

Weakness enumeration for CVE-2017-11579

Affected software / configurations for CVE-2017-11579

Vendor Product Version Raw CPE
blipcare wi-fi_blood_pressure_monitor_firmware <= bp700_10.1 cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:*

References for CVE-2017-11579

cvelogic Threat Intelligence