CVE-2019-10964 | Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

Published: 2019-06-28 Last update: 2026-06-16 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2019-10964 is rated Moderate Risk (51.2/100): CVSS High severity, with medium exploitation likelihood (EPSS 1.16%). Mandatory action: Review affected assets and schedule remediation.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2019-10964

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-06-15 0.40% 1.16% +0.77%
2 2026-05-14 0.34% 0.40% +0.06%
3 2025-11-21 0.34%

Full EPSS history (14 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2019-10964

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
7.1 3.1 HIGH
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:H)
Even with access, the exploit needs extra luck, timing, or a fussy environment to actually work.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:L)
Some sensitive info could get out, but not a total data dump.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
1.6 5.5 [email protected]
8.8 3.0 HIGH
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
2.8 5.9 [email protected]
5.8 2.0 MEDIUM
AV:A/AC:L/Au:N/C:P/I:P/A:P Click to expand
Access vector (AV:A)
Requires access to an adjacent network segment.
Access complexity (AC:L)
Exploitation conditions are straightforward and predictable.
Authentication (AU:N)
No authentication is required.
Confidentiality impact (C:P)
Partial confidentiality impact.
Integrity impact (I:P)
Partial integrity impact.
Availability impact (A:P)
Partial availability impact.
6.5 6.4 [email protected]

Weakness enumeration for CVE-2019-10964

Affected software / configurations for CVE-2019-10964

Vendor Product Version Raw CPE
medtronic minimed_508_firmware cpe:2.3:o:medtronic:minimed_508_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_511_firmware cpe:2.3:o:medtronic:minimed_paradigm_511_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_512_firmware cpe:2.3:o:medtronic:minimed_paradigm_512_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_712_firmware cpe:2.3:o:medtronic:minimed_paradigm_712_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_712e_firmware cpe:2.3:o:medtronic:minimed_paradigm_712e_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_515_firmware cpe:2.3:o:medtronic:minimed_paradigm_515_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_715_firmware cpe:2.3:o:medtronic:minimed_paradigm_715_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_522_firmware cpe:2.3:o:medtronic:minimed_paradigm_522_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_722_firmware cpe:2.3:o:medtronic:minimed_paradigm_722_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_522k_firmware cpe:2.3:o:medtronic:minimed_paradigm_522k_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_722k_firmware cpe:2.3:o:medtronic:minimed_paradigm_722k_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_523_firmware <= 2.4a cpe:2.3:o:medtronic:minimed_paradigm_523_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_723_firmware <= 2.4a cpe:2.3:o:medtronic:minimed_paradigm_723_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_523k_firmware <= 2.4a cpe:2.3:o:medtronic:minimed_paradigm_523k_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_723k_firmware <= 2.4a cpe:2.3:o:medtronic:minimed_paradigm_723k_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_veo_554_firmware <= 2.6a cpe:2.3:o:medtronic:minimed_paradigm_veo_554_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_veo_754_firmware <= 2.6a cpe:2.3:o:medtronic:minimed_paradigm_veo_754_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_veo_554cm_firmware <= 2.7a cpe:2.3:o:medtronic:minimed_paradigm_veo_554cm_firmware:*:*:*:*:*:*:*:*
medtronic minimed_paradigm_veo_754cm_firmware cpe:2.3:o:medtronic:minimed_paradigm_veo_754cm_firmware:-:*:*:*:*:*:*:*

References for CVE-2019-10964

cvelogic Threat Intelligence