CVE-2019-6540 | Medtronic Conexus Radio Frequency Telemetry Protocol Cleartext Transmission of Sensitive Information

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.

Published: 2019-03-26 Last update: 2026-06-16 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2019-6540 is rated Low Risk (29.4/100): CVSS Medium severity, with low exploitation likelihood (EPSS 0.19%). Mandatory action: Monitor for updates and reassess as exploit intelligence or EPSS changes.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2019-6540

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-06-15 0.02% 0.19% +0.18%
2 2025-03-17 0.05% 0.02% -0.04%
3 2023-03-07 0.05%

Full EPSS history (7 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2019-6540

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
6.5 3.1 MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:N)
Data isn’t meaningfully altered or forged.
Availability (A:N)
Service keeps running; no real outage angle.
2.8 3.6 [email protected]
6.5 3.1 MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:N)
Data isn’t meaningfully altered or forged.
Availability (A:N)
Service keeps running; no real outage angle.
2.8 3.6 [email protected]
3.3 2.0 LOW
AV:A/AC:L/Au:N/C:P/I:N/A:N Click to expand
Access vector (AV:A)
Requires access to an adjacent network segment.
Access complexity (AC:L)
Exploitation conditions are straightforward and predictable.
Authentication (AU:N)
No authentication is required.
Confidentiality impact (C:P)
Partial confidentiality impact.
Integrity impact (I:N)
No integrity impact.
Availability impact (A:N)
No availability impact.
6.5 2.9 [email protected]

Weakness enumeration for CVE-2019-6540

Affected software / configurations for CVE-2019-6540

Vendor Product Version Raw CPE
medtronic mycarelink_monitor_24950_firmware cpe:2.3:o:medtronic:mycarelink_monitor_24950_firmware:-:*:*:*:*:*:*:*
medtronic mycarelink_monitor_24952_firmware cpe:2.3:o:medtronic:mycarelink_monitor_24952_firmware:-:*:*:*:*:*:*:*
medtronic carelink_monitor_2490c_firmware cpe:2.3:o:medtronic:carelink_monitor_2490c_firmware:-:*:*:*:*:*:*:*
medtronic carelink_2090_firmware cpe:2.3:o:medtronic:carelink_2090_firmware:-:*:*:*:*:*:*:*
medtronic amplia_crt-d_firmware cpe:2.3:o:medtronic:amplia_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic claria_crt-d_firmware cpe:2.3:o:medtronic:claria_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic compia_crt-d_firmware cpe:2.3:o:medtronic:compia_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic concerto_crt-d_firmware cpe:2.3:o:medtronic:concerto_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic concerto_ii_crt-d_firmware cpe:2.3:o:medtronic:concerto_ii_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic consulta_crt-d_firmware cpe:2.3:o:medtronic:consulta_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic evera_icd_firmware cpe:2.3:o:medtronic:evera_icd_firmware:-:*:*:*:*:*:*:*
medtronic maximo_ii_crt-d_firmware cpe:2.3:o:medtronic:maximo_ii_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic maximo_ii_icd_firmware cpe:2.3:o:medtronic:maximo_ii_icd_firmware:-:*:*:*:*:*:*:*
medtronic mirro_icd_firmware cpe:2.3:o:medtronic:mirro_icd_firmware:-:*:*:*:*:*:*:*
medtronic nayamed_nd_icd_firmware cpe:2.3:o:medtronic:nayamed_nd_icd_firmware:-:*:*:*:*:*:*:*
medtronic primo_icd_firmware cpe:2.3:o:medtronic:primo_icd_firmware:-:*:*:*:*:*:*:*
medtronic protecta_icd_firmware cpe:2.3:o:medtronic:protecta_icd_firmware:-:*:*:*:*:*:*:*
medtronic protecta_crt-d_firmware cpe:2.3:o:medtronic:protecta_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic secura_icd_firmware cpe:2.3:o:medtronic:secura_icd_firmware:-:*:*:*:*:*:*:*
medtronic virtuoso_icd_firmware cpe:2.3:o:medtronic:virtuoso_icd_firmware:-:*:*:*:*:*:*:*
medtronic virtuoso_ii_icd_firmware cpe:2.3:o:medtronic:virtuoso_ii_icd_firmware:-:*:*:*:*:*:*:*
medtronic visia_af_icd_firmware cpe:2.3:o:medtronic:visia_af_icd_firmware:-:*:*:*:*:*:*:*
medtronic viva_crt-d_firmware cpe:2.3:o:medtronic:viva_crt-d_firmware:-:*:*:*:*:*:*:*

References for CVE-2019-6540

URL Tags
http://www.securityfocus.com/bid/107544 Broken Link
https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01 Third Party Advisory US Government Resource
cvelogic Threat Intelligence