A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Conclusion & alert: CVE-2019-6572 is rated Moderate Risk (61.8/100): CVSS Critical severity, with medium exploitation likelihood (EPSS 0.72%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-01 | 0.83% | 0.72% | -0.11% |
| 2 | 2026-04-14 | 0.90% | 0.83% | -0.08% |
| 3 | 2025-03-30 | — | 0.90% | — |
Full EPSS history (14 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 9.1 | 3.1 | CRITICAL |
|
3.9 | 5.2 | [email protected] |
| 6.4 | 2.0 | MEDIUM |
|
10.0 | 4.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| siemens | simatic_hmi_comfort_panels_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_comfort_outdoor_panels_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_wincc_\(tia_portal\) | < 15.1 | cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):*:*:*:*:*:*:*:* |
| siemens | simatic_wincc_runtime | < 15.1 | cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:* |
| siemens | simatic_wincc_runtime | < 15.1 | cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:* |
| siemens | simatic_hmi_tp_firmware | — | cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_mp_firmware | — | cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_op_firmware | — | cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:* |
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/108412 | Third Party Advisory VDB Entry |
| https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | Vendor Advisory |
| https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | Third Party Advisory US Government Resource |