CVE-2020-11677

Exp

Cerner medico 26.00 has a Local Buffer Overflow (issue 3 of 3).

Published: 2020-04-29 Last update: 2024-11-21 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2020-11677 is rated High Exploit Risk (67.5/100): CVSS High severity, with low exploitation likelihood (EPSS 0.26%). Core evidence: 1 public exploit reference(s) are indexed (Exploit-DB). Mandatory action: Public exploits are available—assess exposure, apply mitigations, and prioritize patching.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Public exploit references (Exploit-DB) for CVE-2020-11677

EDB-ID Source Kind Published Link
nvd_ref exploit_tag Exploit-DB ↗

Exploit prediction scoring system (EPSS) score for CVE-2020-11677

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2025-11-21 0.11% 0.26% +0.15%
2 2025-11-18 0.26% 0.11% -0.15%
3 2025-07-13 0.26%

Full EPSS history (10 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2020-11677

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
8.8 3.1 HIGH
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
2.8 5.9 [email protected]
5.8 2.0 MEDIUM
AV:A/AC:L/Au:N/C:P/I:P/A:P Click to expand
Access vector (AV:A)
Requires access to an adjacent network segment.
Access complexity (AC:L)
Exploitation conditions are straightforward and predictable.
Authentication (AU:N)
No authentication is required.
Confidentiality impact (C:P)
Partial confidentiality impact.
Integrity impact (I:P)
Partial integrity impact.
Availability impact (A:P)
Partial availability impact.
6.5 6.4 [email protected]

Weakness enumeration for CVE-2020-11677

Affected software / configurations for CVE-2020-11677

Vendor Product Version Raw CPE
cerner medico 26.00 cpe:2.3:a:cerner:medico:26.00:*:*:*:*:*:*:*

References for CVE-2020-11677

URL Tags
https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/ Exploit Third Party Advisory
cvelogic Threat Intelligence