CVE-2020-25178 | Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information

ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.

Published: 2022-03-18 Last update: 2024-11-21 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2020-25178 is rated Moderate Risk (46.1/100): CVSS High severity, with low exploitation likelihood (EPSS 0.23%). Mandatory action: Review affected assets and schedule remediation.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2020-25178

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2025-11-21 0.07% 0.23% +0.16%
2 2025-11-18 0.23% 0.07% -0.16%
3 2025-04-30 0.23%

Full EPSS history (13 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2020-25178

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
7.5 3.1 HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:H)
Even with access, the exploit needs extra luck, timing, or a fussy environment to actually work.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:R)
A real person has to do something—click, install, enable—otherwise it doesn’t land.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
1.6 5.9 [email protected]
8.8 3.1 HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:R)
A real person has to do something—click, install, enable—otherwise it doesn’t land.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
2.8 5.9 [email protected]
9.3 2.0 HIGH
AV:N/AC:M/Au:N/C:C/I:C/A:C Click to expand
Access vector (AV:N)
Can be exploited remotely over network reachability.
Access complexity (AC:M)
Exploitation needs some favorable conditions, but not exceptional ones.
Authentication (AU:N)
No authentication is required.
Confidentiality impact (C:C)
Complete confidentiality impact.
Integrity impact (I:C)
Complete integrity impact.
Availability impact (A:C)
Complete availability impact.
8.6 10.0 [email protected]

Weakness enumeration for CVE-2020-25178

Affected software / configurations for CVE-2020-25178

Vendor Product Version Raw CPE
schneider-electric easergy_t300_firmware <= 2.7.1 cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*
schneider-electric easergy_c5_firmware < 1.1.0 cpe:2.3:o:schneider-electric:easergy_c5_firmware:*:*:*:*:*:*:*:*
schneider-electric micom_c264_firmware < d6.1 cpe:2.3:o:schneider-electric:micom_c264_firmware:*:*:*:*:*:*:*:*
schneider-electric pacis_gtw_firmware 5.1 cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.1:*:*:*:*:windows:*:*
schneider-electric pacis_gtw_firmware 5.2 cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.2:*:*:*:*:windows:*:*
schneider-electric pacis_gtw_firmware 6.1 cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.1:*:*:*:*:windows:*:*
schneider-electric pacis_gtw_firmware 6.3 cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:linux:*:*
schneider-electric pacis_gtw_firmware 6.3 cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:windows:*:*
schneider-electric saitel_dp_firmware <= 11.06.21 cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*
schneider-electric epas_gtw_firmware 6.4 cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:linux:*:*
schneider-electric epas_gtw_firmware 6.4 cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:windows:*:*
schneider-electric saitel_dr_firmware <= 11.06.12 cpe:2.3:o:schneider-electric:saitel_dr_firmware:*:*:*:*:*:*:*:*
schneider-electric scd2200_firmware <= 10024 cpe:2.3:o:schneider-electric:scd2200_firmware:*:*:*:*:*:*:*:*
rockwellautomation aadvance_controller <= 1.40 cpe:2.3:a:rockwellautomation:aadvance_controller:*:*:*:*:*:*:*:*
rockwellautomation isagraf_free_runtime <= 6.6.8 cpe:2.3:a:rockwellautomation:isagraf_free_runtime:*:*:*:*:*:isagraf6_workbench:*:*
rockwellautomation isagraf_runtime >= 5.0, < 6.0 cpe:2.3:a:rockwellautomation:isagraf_runtime:*:*:*:*:*:*:*:*
rockwellautomation micro810_firmware cpe:2.3:o:rockwellautomation:micro810_firmware:-:*:*:*:*:*:*:*
rockwellautomation micro820_firmware cpe:2.3:o:rockwellautomation:micro820_firmware:-:*:*:*:*:*:*:*
rockwellautomation micro830_firmware cpe:2.3:o:rockwellautomation:micro830_firmware:-:*:*:*:*:*:*:*
rockwellautomation micro850_firmware cpe:2.3:o:rockwellautomation:micro850_firmware:-:*:*:*:*:*:*:*
rockwellautomation micro870_firmware cpe:2.3:o:rockwellautomation:micro870_firmware:-:*:*:*:*:*:*:*
xylem multismart_firmware < 3.2.0 cpe:2.3:o:xylem:multismart_firmware:*:*:*:*:*:*:*:*

References for CVE-2020-25178

cvelogic Threat Intelligence