Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
Conclusion & alert: CVE-2020-6769 is rated High Risk (69/100): CVSS Critical severity, with medium exploitation likelihood (EPSS 2.16%). Core evidence: EPSS rose +1.08% over the last day, indicating growing attacker interest. Mandatory action: High exploitation likelihood—assess exposure and prioritize remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 1.08% | 2.16% | +1.08% |
| 2 | 2025-11-21 | 0.88% | 1.08% | +0.20% |
| 3 | 2025-11-18 | — | 0.88% | — |
Full EPSS history (14 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 10.0 | 3.1 | CRITICAL |
|
3.9 | 6.0 | [email protected] |
| 9.1 | 3.1 | CRITICAL |
|
3.9 | 5.2 | [email protected] |
| 6.4 | 2.0 | MEDIUM |
|
10.0 | 4.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| bosch | video_streaming_gateway | <= 6.42.10 | cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:* |
| bosch | video_streaming_gateway | >= 6.43, <= 6.43.0023 | cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:* |
| bosch | video_streaming_gateway | >= 6.44, <= 6.44.022 | cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:* |
| bosch | video_streaming_gateway | >= 6.45, <= 6.45.08 | cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:* |
| bosch | divar_ip_2000_firmware | <= 3.62.0019 | cpe:2.3:o:bosch:divar_ip_2000_firmware:*:*:*:*:*:*:*:* |
| bosch | divar_ip_5000_firmware | <= 3.80.0039 | cpe:2.3:o:bosch:divar_ip_5000_firmware:*:*:*:*:*:*:*:* |
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html | Patch Vendor Advisory |