The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Conclusion & alert: CVE-2021-27410 is rated Moderate Risk (58.9/100): CVSS Critical severity, with medium exploitation likelihood (EPSS 0.34%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-04-04 | 0.55% | 0.34% | -0.21% |
| 2 | 2025-11-24 | 0.24% | 0.55% | +0.31% |
| 3 | 2025-11-21 | — | 0.24% | — |
Full EPSS history (16 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 9.8 | 3.1 | CRITICAL |
|
3.9 | 5.9 | [email protected] |
| 7.5 | 2.0 | HIGH |
|
10.0 | 6.4 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| hillrom | connex_central_station | < 1.8.6 | cpe:2.3:a:hillrom:connex_central_station:*:*:*:*:*:*:*:* |
| hillrom | connex_device_integration_suite_network_connectivity_engine | < 5.3 | cpe:2.3:a:hillrom:connex_device_integration_suite_network_connectivity_engine:*:*:*:*:*:*:*:* |
| hillrom | connex_integrated_wall_system | < 2.43.02 | cpe:2.3:a:hillrom:connex_integrated_wall_system:*:*:*:*:*:*:*:* |
| hillrom | connex_spot_monitor | < 1.52 | cpe:2.3:a:hillrom:connex_spot_monitor:*:*:*:*:*:*:*:* |
| hillrom | connex_vital_signs_monitor | < 2.43.02 | cpe:2.3:a:hillrom:connex_vital_signs_monitor:*:*:*:*:*:*:*:* |
| hillrom | service_monitor | < 1.7.0.0 | cpe:2.3:a:hillrom:service_monitor:*:*:*:*:*:*:*:* |
| hillrom | service_tool | < 1.10 | cpe:2.3:a:hillrom:service_tool:*:*:*:*:*:*:*:* |
| hillrom | software_development_kit | < 3.2 | cpe:2.3:a:hillrom:software_development_kit:*:*:*:*:*:*:*:* |
| hillrom | spot_vital_signs_4400 | < 1.11.00 | cpe:2.3:a:hillrom:spot_vital_signs_4400:*:*:*:*:-:*:*:* |
| hillrom | spot_vital_signs_4400 | < 1.11.00 | cpe:2.3:a:hillrom:spot_vital_signs_4400:*:*:*:*:extended_care:*:*:* |
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01 | Mitigation Third Party Advisory US Government Resource |