A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
Conclusion & alert: CVE-2021-31883 is rated Moderate Risk (53.1/100): CVSS High severity, with medium exploitation likelihood (EPSS 1.48%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 1.41% | 1.48% | +0.06% |
| 2 | 2025-04-20 | 0.86% | 1.41% | +0.55% |
| 3 | 2025-03-30 | — | 0.86% | — |
Full EPSS history (14 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 7.1 | 3.1 | HIGH |
|
2.8 | 4.2 | [email protected] |
| 7.5 | 3.1 | HIGH |
|
3.9 | 3.6 | [email protected] |
| 5.0 | 2.0 | MEDIUM |
|
10.0 | 2.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| siemens | capital_vstar | — | cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:* |
| siemens | nucleus_net | — | cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* |
| siemens | nucleus_readystart_v3 | < 2017.02.1 | cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* |
| siemens | nucleus_source_code | — | cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:* |
| siemens | apogee_modular_building_controller_firmware | — | cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* |
| siemens | apogee_modular_equiment_controller_firmware | — | cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:* |
| siemens | apogee_pxc_compact_firmware | — | cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:* |
| siemens | apogee_pxc_modular_firmware | — | cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:* |
| siemens | talon_tc_compact_firmware | — | cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:* |
| siemens | talon_tc_modular_firmware | — | cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:* |