A Buffer Overflow in Thrift command handlers in IDEMIA Morpho Wave Compact and VisionPass devices before 2.6.2, Sigma devices before 4.9.4, and MA VP MD devices before 4.9.7 allows remote attackers to achieve code execution, denial of services, and information disclosure via TCP/IP packets.
Conclusion & alert: CVE-2021-35522 is rated High Risk (69.6/100): CVSS Critical severity, with medium exploitation likelihood (EPSS 3.66%). Mandatory action: High exploitation likelihood—assess exposure and prioritize remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 4.10% | 3.66% | -0.44% |
| 2 | 2025-09-29 | 3.42% | 4.10% | +0.68% |
| 3 | 2025-03-30 | — | 3.42% | — |
Full EPSS history (18 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 9.8 | 3.1 | CRITICAL |
|
3.9 | 5.9 | [email protected] |
| 9.0 | 2.0 | HIGH |
|
10.0 | 8.5 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| idemia | morphowave_compact_mdpi_firmware | < 2.6.2 | cpe:2.3:o:idemia:morphowave_compact_mdpi_firmware:*:*:*:*:*:*:*:* |
| idemia | morphowave_compact_mdpi-m_firmware | < 2.6.2 | cpe:2.3:o:idemia:morphowave_compact_mdpi-m_firmware:*:*:*:*:*:*:*:* |
| idemia | visionpass_mdpi_firmware | < 2.6.2 | cpe:2.3:o:idemia:visionpass_mdpi_firmware:*:*:*:*:*:*:*:* |
| idemia | visionpass_mdpi-m_firmware | < 2.6.2 | cpe:2.3:o:idemia:visionpass_mdpi-m_firmware:*:*:*:*:*:*:*:* |
| idemia | visionpass_md_firmware | — | cpe:2.3:o:idemia:visionpass_md_firmware:-:*:*:*:*:*:*:* |
| idemia | morphowave_compact_md_firmware | — | cpe:2.3:o:idemia:morphowave_compact_md_firmware:-:*:*:*:*:*:*:* |
| idemia | sigma_lite_firmware | — | cpe:2.3:o:idemia:sigma_lite_firmware:-:*:*:*:*:*:*:* |
| idemia | sigma_lite\+_firmware | — | cpe:2.3:o:idemia:sigma_lite\+_firmware:-:*:*:*:*:*:*:* |
| idemia | sigma_wide_firmware | — | cpe:2.3:o:idemia:sigma_wide_firmware:-:*:*:*:*:*:*:* |
| idemia | sigma_extreme_firmware | — | cpe:2.3:o:idemia:sigma_extreme_firmware:-:*:*:*:*:*:*:* |
| idemia | ma_vp_md_firmware | — | cpe:2.3:o:idemia:ma_vp_md_firmware:-:*:*:*:*:*:*:* |
| URL | Tags |
|---|---|
| https://biometricdevices.idemia.com/s/global-search/0696700000JJa0zAAD?sharing=true | Patch Vendor Advisory |
| https://biometricdevices.idemia.com/s/global-search/0696700000JJa1nAAD?sharing=true | Patch Vendor Advisory |
| https://www.idemia.com | Product |