Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type.
Conclusion & alert: CVE-2022-22508 is rated Moderate Risk (43.5/100): CVSS Medium severity, with medium exploitation likelihood (EPSS 0.82%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-05-30 | 0.62% | 0.82% | +0.20% |
| 2 | 2026-05-29 | 0.15% | 0.62% | +0.47% |
| 3 | 2026-05-26 | — | 0.15% | — |
Full EPSS history (8 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 4.3 | 3.1 | MEDIUM |
|
2.8 | 1.4 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| codesys | control_for_beaglebone_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_empc-a\/imx6_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_iot2000_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_linux_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_pfc100_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_pfc200_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_plcnext_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_raspberry_pi_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_wago_touch_panels_600_sl | < 4.7.0.0 | cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
| codesys | control_rte_\(for_beckhoff_cx\)_sl | < 3.5.18.40 | cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
| codesys | control_rte_\(sl\) | < 3.5.18.40 | cpe:2.3:a:codesys:control_rte_\(sl\):*:*:*:*:*:*:*:* |
| codesys | control_runtime_system_toolkit | < 3.5.18.40 | cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:* |
| codesys | control_win_\(sl\) | < 3.5.18.40 | cpe:2.3:a:codesys:control_win_\(sl\):*:*:*:*:*:*:*:* |
| codesys | hmi_\(sl\) | < 3.5.18.40 | cpe:2.3:a:codesys:hmi_\(sl\):*:*:*:*:*:*:*:* |