CVE-2022-39064

An attacker sending a single malformed IEEE 802.15.4 (Zigbee) frame makes the TRÅDFRI bulb blink, and if they replay (i.e. resend) the same frame multiple times, the bulb performs a factory reset. This causes the bulb to lose configuration information about the Zigbee network and current brightness level. After this attack, all lights are on with full brightness, and a user cannot control the bulbs with either the IKEA Home Smart app or the TRÅDFRI remote control. The malformed Zigbee frame is an unauthenticated broadcast message, which means all vulnerable devices within radio range are affected. CVSS 3.1 Base Score 7.1 vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H

Published: 2022-10-14 Last update: 2025-05-15 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2022-39064 is rated Moderate Risk (41.5/100): CVSS High severity, with low exploitation likelihood (EPSS 0.09%). Mandatory action: Review affected assets and schedule remediation.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2022-39064

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2025-10-19 0.25% 0.09% -0.16%
2 2025-10-15 0.05% 0.25% +0.20%
3 2024-03-26 0.05%

Full EPSS history (5 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2022-39064

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
8.1 3.1 HIGH
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:N)
Doesn’t really leak secrets in a meaningful way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
2.8 5.2 [email protected]
8.1 3.1 HIGH
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H Click to expand
Attack vector (AV:A)
Attacker has to be nearby on the network—same office, same link, that vibe—not the whole wide internet.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:N)
Doesn’t really leak secrets in a meaningful way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
2.8 5.2 134c704f-9b21-4f2e-91b3-4a467353bcc0

Weakness enumeration for CVE-2022-39064

Affected software / configurations for CVE-2022-39064

Vendor Product Version Raw CPE
ikea tradfri_led1732g11_firmware cpe:2.3:o:ikea:tradfri_led1732g11_firmware:-:*:*:*:*:*:*:*

References for CVE-2022-39064

cvelogic Threat Intelligence