In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
Conclusion & alert: CVE-2022-4224 is rated Moderate Risk (54/100): CVSS High severity, with medium exploitation likelihood (EPSS 0.88%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 1.13% | 0.88% | -0.24% |
| 2 | 2026-04-05 | 0.97% | 1.13% | +0.16% |
| 3 | 2026-04-04 | — | 0.97% | — |
Full EPSS history (13 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 8.8 | 3.1 | HIGH |
|
2.8 | 5.9 | [email protected] |
| 8.8 | 3.1 | HIGH |
|
2.8 | 5.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| codesys | control_for_beaglebone_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_empc-a\/imx6_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_iot2000_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_linux_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_pfc100_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_pfc200_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_plcnext_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_raspberry_pi_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* |
| codesys | control_for_wago_touch_panels_600_sl | >= 3.0, < 4.8.0.0 | cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
| codesys | control_rte_sl | >= 3.0, < 3.5.19.0 | cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:* |
| codesys | control_rte_sl_\(for_beckhoff_cx\) | >= 3.0, < 3.5.19.0 | cpe:2.3:a:codesys:control_rte_sl_\(for_beckhoff_cx\):*:*:*:*:*:*:*:* |
| codesys | control_win_sl | >= 3.0, < 3.5.19.0 | cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:* |
| codesys | development_system | >= 3.0, < 3.5.19.0 | cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:* |
| codesys | hmi_sl | >= 3.0, < 3.5.19.0 | cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:* |
| codesys | runtime_toolkit | >= 3.0, < 3.5.19.0 | cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
| codesys | safety_sil2 | >= 3.0, < 3.5.19.0 | cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:* |