CVE-2023-22610

A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.

Published: 2023-01-31 Last update: 2026-06-17 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2023-22610 is rated Moderate Risk (51.3/100): CVSS Critical severity, with low exploitation likelihood (EPSS 0.57%). Mandatory action: Review affected assets and schedule remediation.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2023-22610

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-06-15 0.48% 0.57% +0.09%
2 2026-02-01 0.27% 0.48% +0.21%
3 2025-11-21 0.27%

Full EPSS history (9 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2023-22610

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
9.1 3.1 CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:N)
Doesn’t really leak secrets in a meaningful way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
3.9 5.2 [email protected]
7.5 3.1 HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:N)
Doesn’t really leak secrets in a meaningful way.
Integrity (I:N)
Data isn’t meaningfully altered or forged.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
3.9 3.6 [email protected]

Weakness enumeration for CVE-2023-22610

Affected software / configurations for CVE-2023-22610

Vendor Product Version Raw CPE
schneider-electric ecostruxure_geo_scada_expert_2019 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:-:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7268.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7268.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7322.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7322.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7429.2 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7429.2:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7457.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7457.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7488.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7488.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7522.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7522.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7545.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7545.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7578.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7578.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7613.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7613.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7641.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7641.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7690.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7690.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7714.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7714.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7742.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7742.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7777.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7777.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7808.2 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7808.2:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7840.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7840.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7875.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7875.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7896.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7896.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7936.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7936.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.7980.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7980.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8015.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8015.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8108.2 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8108.2:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8122.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8122.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8155.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8155.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8172.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8172.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8197.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8197.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8220.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8220.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2019 81.8267.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8267.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:-:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7551.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7551.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7578.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7578.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7613.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7613.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7641.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7641.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7692.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7692.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7717.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7717.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7742.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7742.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7787.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7787.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7809.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7809.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7840.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7840.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7875.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7875.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7913.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7913.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7936.2 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7936.2:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.7980.2 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7980.2:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8017.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8017.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8108.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8108.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8122.2 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8122.2:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8155.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8155.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8181.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8181.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8197.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8197.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8221.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8221.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2020 83.8267.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8267.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:-:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8027.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8027.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8108.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8108.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8120.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8120.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8158.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8158.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8182.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8182.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8197.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8197.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8218.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8218.1:*:*:*:*:*:*:*
schneider-electric ecostruxure_geo_scada_expert_2021 84.8269.1 cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8269.1:*:*:*:*:*:*:*

References for CVE-2023-22610

cvelogic Threat Intelligence