An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details.
Conclusion & alert: CVE-2023-31159 is rated Low Risk (29.6/100): CVSS Medium severity, with low exploitation likelihood (EPSS 0.44%). Mandatory action: Monitor for updates and reassess as exploit intelligence or EPSS changes.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 0.20% | 0.44% | +0.24% |
| 2 | 2026-05-18 | 0.28% | 0.20% | -0.08% |
| 3 | 2026-05-11 | — | 0.28% | — |
Full EPSS history (9 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 4.3 | 3.1 | MEDIUM |
|
0.9 | 3.4 | [email protected] |
| 5.4 | 3.1 | MEDIUM |
|
2.3 | 2.7 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| selinc | sel-2241_rtac_module_firmware | >= r113-v0, < r150-v2 | cpe:2.3:o:selinc:sel-2241_rtac_module_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3350_firmware | >= r148-v0, < r150-v2 | cpe:2.3:o:selinc:sel-3350_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3505_firmware | >= r119-v0, < r150-v2 | cpe:2.3:o:selinc:sel-3505_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3505-3_firmware | >= r132-v0, < r150-v2 | cpe:2.3:o:selinc:sel-3505-3_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3530_firmware | >= r100-v0, < r150-v2 | cpe:2.3:o:selinc:sel-3530_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3530-4_firmware | >= r108-v0, < r150-v2 | cpe:2.3:o:selinc:sel-3530-4_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3532_firmware | >= r132-v0, < r150-v2 | cpe:2.3:o:selinc:sel-3532_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3555_firmware | >= r134-v0, < r150-v2 | cpe:2.3:o:selinc:sel-3555_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3560e_firmware | >= r144-v2, < r150-v2 | cpe:2.3:o:selinc:sel-3560e_firmware:*:*:*:*:*:*:*:* |
| selinc | sel-3560s_firmware | >= r144-v2, < r150-v2 | cpe:2.3:o:selinc:sel-3560s_firmware:*:*:*:*:*:*:*:* |
| URL | Tags |
|---|---|
| https://selinc.com/support/security-notifications/external-reports/ | Vendor Advisory |
| https://www.nozominetworks.com/blog/ | Third Party Advisory |