CVE-2023-38936

Exp

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.

Published: 2023-08-07 Last update: 2024-11-21 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2023-38936 is rated High Exploit Risk (71.4/100): CVSS Critical severity, with low exploitation likelihood (EPSS 0.71%). Core evidence: 1 public exploit reference(s) are indexed (Exploit-DB). Mandatory action: Public exploits are available—assess exposure, apply mitigations, and prioritize patching.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Public exploit references (Exploit-DB) for CVE-2023-38936

EDB-ID Source Kind Published Link
nvd_ref exploit_tag Exploit-DB ↗

Exploit prediction scoring system (EPSS) score for CVE-2023-38936

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-06-15 0.47% 0.71% +0.24%
2 2026-06-03 0.42% 0.47% +0.06%
3 2026-05-02 0.42%

Full EPSS history (12 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2023-38936

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
9.8 3.1 CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
3.9 5.9 [email protected]

Weakness enumeration for CVE-2023-38936

Affected software / configurations for CVE-2023-38936

Vendor Product Version Raw CPE
tenda ac10_firmware 15.03.06.23 cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*
tenda ac1206_firmware 15.03.06.23 cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*
tenda ac6_firmware 15.03.06.23 cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*
tenda ac7_firmware 15.03.06.44 cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
tenda f1203_firmware 2.0.1.6 cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*
tenda ac5_firmware 15.03.06.28 cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*
tenda fh1203_firmware 2.0.1.6 cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*
tenda fh1205_firmware 2.0.0.7\(775\) cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\(775\):*:*:*:*:*:*:*
tenda ac9_firmware 15.03.06.42_multi cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*

References for CVE-2023-38936