CVE-2023-39466 | Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability

Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.

Published: 2024-05-03 Last update: 2025-06-17 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2023-39466 is rated Moderate Risk (41.5/100): CVSS Medium severity, with medium exploitation likelihood (EPSS 0.93%). Mandatory action: Review affected assets and schedule remediation.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2023-39466

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-06-15 0.11% 0.93% +0.81%
2 2025-11-21 0.22% 0.11% -0.11%
3 2025-11-18 0.22%

Full EPSS history (6 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2023-39466

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
5.3 3.0 MEDIUM
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:L)
Some sensitive info could get out, but not a total data dump.
Integrity (I:N)
Data isn’t meaningfully altered or forged.
Availability (A:N)
Service keeps running; no real outage angle.
3.9 1.4 [email protected]

Weakness enumeration for CVE-2023-39466

Affected software / configurations for CVE-2023-39466

Vendor Product Version Raw CPE
trianglemicroworks scada_data_gateway 5.1.3.20324 cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*

References for CVE-2023-39466