Dell PowerEdge platforms 16G Intel E5 BIOS and Dell Precision BIOS, version 1.4.4, contain active debug code security vulnerability. An unauthenticated physical attacker could potentially exploit this vulnerability, leading to information disclosure, information tampering, code execution, denial of service.
Conclusion & alert: CVE-2023-44297 is rated Low Risk (34.4/100): CVSS High severity, with low exploitation likelihood (EPSS 0.25%). Mandatory action: Monitor for updates and reassess as exploit intelligence or EPSS changes.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 0.03% | 0.25% | +0.23% |
| 2 | 2025-11-21 | 0.07% | 0.03% | -0.04% |
| 3 | 2025-11-18 | — | 0.07% | — |
Full EPSS history (6 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 7.1 | 3.1 | HIGH |
|
0.5 | 6.0 | [email protected] |
| 6.8 | 3.1 | MEDIUM |
|
0.9 | 5.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| dell | poweredge_r660_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r660_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_r760_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r760_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_c6620_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_c6620_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_mx760c_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_mx760c_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_r860_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r860_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_r960_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r960_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_hs5610_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_hs5610_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_hs5620_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_hs5620_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_r660xs_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r660xs_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_r760xs_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r760xs_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_r760xd2_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r760xd2_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_t560_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_t560_firmware:1.4.4:*:*:*:*:*:*:* |
| dell | poweredge_r760xa_firmware | 1.4.4 | cpe:2.3:o:dell:poweredge_r760xa_firmware:1.4.4:*:*:*:*:*:*:* |