Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
Conclusion & alert: CVE-2023-6943 is rated Moderate Risk (63.7/100): CVSS Critical severity, with medium exploitation likelihood (EPSS 1.84%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 3.97% | 1.84% | -2.13% |
| 2 | 2025-11-21 | 0.85% | 3.97% | +3.12% |
| 3 | 2025-11-18 | — | 0.85% | — |
Full EPSS history (13 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 9.8 | 3.1 | CRITICAL |
|
3.9 | 5.9 | [email protected] |
| 9.8 | 3.1 | CRITICAL |
|
3.9 | 5.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| mitsubishielectric | ezsocket | >= 3.0 | cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:* |
| mitsubishielectric | fr_configurator2 | — | cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:* |
| mitsubishielectric | got1000 | — | cpe:2.3:a:mitsubishielectric:got1000:*:*:*:*:*:*:*:* |
| mitsubishielectric | got2000 | — | cpe:2.3:a:mitsubishielectric:got2000:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_works2 | >= 1.11m | cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_works3 | — | cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:* |
| mitsubishielectric | mc_works64 | — | cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:* |
| mitsubishielectric | melsoft_navigator | >= 1.04e | cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:* |
| mitsubishielectric | mt_works2 | — | cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:* |
| mitsubishielectric | mx_component | >= 4.00a | cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:* |
| URL | Tags |
|---|---|
| https://jvn.jp/vu/JVNVU95103362 | Third Party Advisory |
| https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 | Third Party Advisory US Government Resource |
| https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf | Vendor Advisory |