CVE-2024-0161

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A local low privileged attacker could potentially exploit this vulnerability leading to arbitrary writes to SMRAM.

Published: 2024-03-13 Last update: 2026-06-17 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2024-0161 is rated Low Risk (32.6/100): CVSS High severity, with low exploitation likelihood (EPSS 0.20%). Mandatory action: Monitor for updates and reassess as exploit intelligence or EPSS changes.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2024-0161

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-06-15 0.04% 0.20% +0.16%
2 2025-04-21 0.06% 0.04% -0.01%
3 2025-04-20 0.06%

Full EPSS history (6 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2024-0161

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
7.2 3.1 HIGH
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:H Click to expand
Attack vector (AV:L)
They already need access on the box, or another person has to do something wrong; it’s not a remote drive-by.
Attack complexity (AC:H)
Even with access, the exploit needs extra luck, timing, or a fussy environment to actually work.
Privileges required (PR:H)
They need powerful rights—admin, root, or similar—before this pays off.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:C)
Breaking this can reach past the original component and bite other resources—bigger blast radius.
Confidentiality (C:N)
Doesn’t really leak secrets in a meaningful way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
0.8 5.8 [email protected]
8.4 3.1 HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H Click to expand
Attack vector (AV:L)
They already need access on the box, or another person has to do something wrong; it’s not a remote drive-by.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:L)
A normal user session is enough; they don’t have to be admin.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:C)
Breaking this can reach past the original component and bite other resources—bigger blast radius.
Confidentiality (C:N)
Doesn’t really leak secrets in a meaningful way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
2.0 5.8 [email protected]

Weakness enumeration for CVE-2024-0161

Affected software / configurations for CVE-2024-0161

Vendor Product Version Raw CPE
dell poweredge_t360_firmware < 1.1.1 cpe:2.3:o:dell:poweredge_t360_firmware:*:*:*:*:*:*:*:*
dell poweredge_r360_firmware < 1.1.1 cpe:2.3:o:dell:poweredge_r360_firmware:*:*:*:*:*:*:*:*
dell poweredge_r650_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_r650_firmware:*:*:*:*:*:*:*:*
dell poweredge_r750_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_r750_firmware:*:*:*:*:*:*:*:*
dell poweredge_r750xa_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_r750xa_firmware:*:*:*:*:*:*:*:*
dell poweredge_c6520_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_c6520_firmware:*:*:*:*:*:*:*:*
dell poweredge_mx750c_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_mx750c_firmware:*:*:*:*:*:*:*:*
dell poweredge_r550_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_r550_firmware:*:*:*:*:*:*:*:*
dell poweredge_r450_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_r450_firmware:*:*:*:*:*:*:*:*
dell poweredge_r650xs_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_r650xs_firmware:*:*:*:*:*:*:*:*
dell poweredge_r750xs_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_r750xs_firmware:*:*:*:*:*:*:*:*
dell poweredge_t550_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_t550_firmware:*:*:*:*:*:*:*:*
dell poweredge_xr11_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_xr11_firmware:*:*:*:*:*:*:*:*
dell poweredge_xr12_firmware < 1.13.2 cpe:2.3:o:dell:poweredge_xr12_firmware:*:*:*:*:*:*:*:*
dell poweredge_xr4510c_firmware < 1.14.1 cpe:2.3:o:dell:poweredge_xr4510c_firmware:*:*:*:*:*:*:*:*
dell poweredge_xr4520c_firmware < 1.14.1 cpe:2.3:o:dell:poweredge_xr4520c_firmware:*:*:*:*:*:*:*:*
dell poweredge_t150_firmware < 1.9.1 cpe:2.3:o:dell:poweredge_t150_firmware:*:*:*:*:*:*:*:*
dell poweredge_t350_firmware < 1.9.1 cpe:2.3:o:dell:poweredge_t350_firmware:*:*:*:*:*:*:*:*
dell poweredge_r250_firmware < 1.9.1 cpe:2.3:o:dell:poweredge_r250_firmware:*:*:*:*:*:*:*:*
dell poweredge_r350_firmware < 1.9.1 cpe:2.3:o:dell:poweredge_r350_firmware:*:*:*:*:*:*:*:*
dell poweredge_r740_firmware < 2.21.2 cpe:2.3:o:dell:poweredge_r740_firmware:*:*:*:*:*:*:*:*
dell poweredge_r740xd_firmware < 2.21.2 cpe:2.3:o:dell:poweredge_r740xd_firmware:*:*:*:*:*:*:*:*
dell poweredge_r640_firmware < 2.21.2 cpe:2.3:o:dell:poweredge_r640_firmware:*:*:*:*:*:*:*:*
dell poweredge_r940_firmware < 2.21.2 cpe:2.3:o:dell:poweredge_r940_firmware:*:*:*:*:*:*:*:*
dell poweredge_r540_firmware < 2.21.1 cpe:2.3:o:dell:poweredge_r540_firmware:*:*:*:*:*:*:*:*
dell poweredge_r440_firmware < 2.21.1 cpe:2.3:o:dell:poweredge_r440_firmware:*:*:*:*:*:*:*:*
dell poweredge_t440_firmware < 2.21.1 cpe:2.3:o:dell:poweredge_t440_firmware:*:*:*:*:*:*:*:*
dell poweredge_xr2_firmware < 2.21.1 cpe:2.3:o:dell:poweredge_xr2_firmware:*:*:*:*:*:*:*:*
dell poweredge_r740xd2_firmware < 2.21.1 cpe:2.3:o:dell:poweredge_r740xd2_firmware:*:*:*:*:*:*:*:*
dell poweredge_r840_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_r840_firmware:*:*:*:*:*:*:*:*
dell poweredge_r940xa_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_r940xa_firmware:*:*:*:*:*:*:*:*
dell poweredge_t640_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_t640_firmware:*:*:*:*:*:*:*:*
dell poweredge_c6420_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_c6420_firmware:*:*:*:*:*:*:*:*
dell poweredge_fc640_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_fc640_firmware:*:*:*:*:*:*:*:*
dell poweredge_m640_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_m640_firmware:*:*:*:*:*:*:*:*
dell poweredge_m640_\(pe_vrtx\)_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_m640_\(pe_vrtx\)_firmware:*:*:*:*:*:*:*:*
dell poweredge_mx740c_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_mx740c_firmware:*:*:*:*:*:*:*:*
dell poweredge_mx840c_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_mx840c_firmware:*:*:*:*:*:*:*:*
dell poweredge_c4140_firmware < 2.21.1 cpe:2.3:o:dell:poweredge_c4140_firmware:*:*:*:*:*:*:*:*
dell dss_8440_firmware < 2.21.0 cpe:2.3:o:dell:dss_8440_firmware:*:*:*:*:*:*:*:*
dell poweredge_xe2420_firmware < 2.21.1 cpe:2.3:o:dell:poweredge_xe2420_firmware:*:*:*:*:*:*:*:*
dell poweredge_xe7420_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_xe7420_firmware:*:*:*:*:*:*:*:*
dell poweredge_xe7440_firmware < 2.21.0 cpe:2.3:o:dell:poweredge_xe7440_firmware:*:*:*:*:*:*:*:*
dell poweredge_r730_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_r730_firmware:*:*:*:*:*:*:*:*
dell poweredge_r730xd_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_r730xd_firmware:*:*:*:*:*:*:*:*
dell poweredge_r630_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_r630_firmware:*:*:*:*:*:*:*:*
dell poweredge_c4130_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_c4130_firmware:*:*:*:*:*:*:*:*
dell poweredge_r930_firmware < 2.14.0 cpe:2.3:o:dell:poweredge_r930_firmware:*:*:*:*:*:*:*:*
dell poweredge_m630_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_m630_firmware:*:*:*:*:*:*:*:*
dell poweredge_m630_\(pe_vrtx\)_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_m630_\(pe_vrtx\)_firmware:*:*:*:*:*:*:*:*
dell poweredge_fc630_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_fc630_firmware:*:*:*:*:*:*:*:*
dell poweredge_fc430_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_fc430_firmware:*:*:*:*:*:*:*:*
dell poweredge_m830_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_m830_firmware:*:*:*:*:*:*:*:*
dell poweredge_m830_\(pe_vrtx\)_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_m830_\(pe_vrtx\)_firmware:*:*:*:*:*:*:*:*
dell poweredge_fc830_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_fc830_firmware:*:*:*:*:*:*:*:*
dell poweredge_t630_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_t630_firmware:*:*:*:*:*:*:*:*
dell poweredge_r530_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_r530_firmware:*:*:*:*:*:*:*:*
dell poweredge_r430_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_r430_firmware:*:*:*:*:*:*:*:*
dell poweredge_t430_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_t430_firmware:*:*:*:*:*:*:*:*
dell poweredge_r830_firmware < 1.19.0 cpe:2.3:o:dell:poweredge_r830_firmware:*:*:*:*:*:*:*:*
dell poweredge_c6320_firmware < 2.19.0 cpe:2.3:o:dell:poweredge_c6320_firmware:*:*:*:*:*:*:*:*
dell poweredge_t130_firmware < 2.20.0 cpe:2.3:o:dell:poweredge_t130_firmware:*:*:*:*:*:*:*:*
dell poweredge_r230_firmware < 2.20.0 cpe:2.3:o:dell:poweredge_r230_firmware:*:*:*:*:*:*:*:*
dell poweredge_t330_firmware < 2.20.0 cpe:2.3:o:dell:poweredge_t330_firmware:*:*:*:*:*:*:*:*
dell poweredge_r330_firmware < 2.20.0 cpe:2.3:o:dell:poweredge_r330_firmware:*:*:*:*:*:*:*:*
dell emc_storage_nx3240_firmware < 2.21.2 cpe:2.3:o:dell:emc_storage_nx3240_firmware:*:*:*:*:*:*:*:*
dell emc_storage_nx3340_firmware < 2.21.2 cpe:2.3:o:dell:emc_storage_nx3340_firmware:*:*:*:*:*:*:*:*
dell storage_nx3230_firmware < 2.19.0 cpe:2.3:o:dell:storage_nx3230_firmware:*:*:*:*:*:*:*:*
dell storage_nx3330_firmware < 2.19.0 cpe:2.3:o:dell:storage_nx3330_firmware:*:*:*:*:*:*:*:*
dell storage_nx430_firmware < 2.20.0 cpe:2.3:o:dell:storage_nx430_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc450_firmware < 1.13.2 cpe:2.3:o:dell:emc_xc_core_xc450_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc650_firmware < 1.13.2 cpe:2.3:o:dell:emc_xc_core_xc650_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc750_firmware < 1.13.2 cpe:2.3:o:dell:emc_xc_core_xc750_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc750xa_firmware < 1.13.2 cpe:2.3:o:dell:emc_xc_core_xc750xa_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc6520_firmware < 1.13.2 cpe:2.3:o:dell:emc_xc_core_xc6520_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_6420_firmware < 2.21.0 cpe:2.3:o:dell:emc_xc_core_6420_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc640_firmware < 2.21.2 cpe:2.3:o:dell:emc_xc_core_xc640_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc740xd_firmware < 2.21.2 cpe:2.3:o:dell:emc_xc_core_xc740xd_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc740xd2_firmware < 2.21.1 cpe:2.3:o:dell:emc_xc_core_xc740xd2_firmware:*:*:*:*:*:*:*:*
dell emc_xc_core_xc940_firmware < 2.21.2 cpe:2.3:o:dell:emc_xc_core_xc940_firmware:*:*:*:*:*:*:*:*

References for CVE-2024-0161

cvelogic Threat Intelligence