A maliciously crafted DWG file, when parsed through certain Autodesk applications, can force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process.
Conclusion & alert: CVE-2025-1276 is rated Moderate Risk (42.9/100): CVSS High severity, with low exploitation likelihood (EPSS 0.14%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-05-27 | 0.18% | 0.14% | -0.04% |
| 2 | 2026-05-26 | 0.06% | 0.18% | +0.12% |
| 3 | 2026-02-09 | — | 0.06% | — |
Full EPSS history (4 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 7.8 | 3.1 | HIGH |
|
1.8 | 5.9 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| autodesk | advance_steel | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:* |
| autodesk | advance_steel | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:* |
| autodesk | advance_steel | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:* |
| autodesk | autocad | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad:*:*:*:*:*:-:*:* |
| autodesk | autocad | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad:*:*:*:*:*:-:*:* |
| autodesk | autocad | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad:*:*:*:*:*:-:*:* |
| autodesk | autocad_architecture | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:* |
| autodesk | autocad_architecture | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:* |
| autodesk | autocad_architecture | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:* |
| autodesk | autocad_electrical | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:* |
| autodesk | autocad_electrical | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:* |
| autodesk | autocad_electrical | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:* |
| autodesk | autocad_lt | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:-:*:* |
| autodesk | autocad_lt | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:-:*:* |
| autodesk | autocad_lt | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:-:*:* |
| autodesk | autocad_map_3d | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:* |
| autodesk | autocad_map_3d | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:* |
| autodesk | autocad_map_3d | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:* |
| autodesk | autocad_mechanical | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:* |
| autodesk | autocad_mechanical | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:* |
| autodesk | autocad_mechanical | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:* |
| autodesk | autocad_mep | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:* |
| autodesk | autocad_mep | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:* |
| autodesk | autocad_mep | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:* |
| autodesk | autocad_plant_3d | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:* |
| autodesk | autocad_plant_3d | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:* |
| autodesk | autocad_plant_3d | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:* |
| autodesk | civil_3d | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:* |
| autodesk | civil_3d | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:* |
| autodesk | civil_3d | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:* |
| autodesk | dwg_trueview | >= 2023, < 2023.1.7 | cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:* |
| autodesk | dwg_trueview | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:* |
| autodesk | dwg_trueview | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:* |
| autodesk | infrastructure_parts_editor | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:infrastructure_parts_editor:*:*:*:*:*:*:*:* |
| autodesk | infrastructure_parts_editor | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:infrastructure_parts_editor:*:*:*:*:*:*:*:* |
| autodesk | inventor | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:inventor:*:*:*:*:*:*:*:* |
| autodesk | inventor | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:inventor:*:*:*:*:*:*:*:* |
| autodesk | navisworks_manage | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:navisworks_manage:*:*:*:*:*:*:*:* |
| autodesk | navisworks_manage | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:navisworks_manage:*:*:*:*:*:*:*:* |
| autodesk | navisworks_simulate | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:navisworks_simulate:*:*:*:*:*:*:*:* |
| autodesk | navisworks_simulate | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:navisworks_simulate:*:*:*:*:*:*:*:* |
| autodesk | revit | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:* |
| autodesk | revit | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:* |
| autodesk | vault | >= 2024, < 2024.1.7 | cpe:2.3:a:autodesk:vault:*:*:*:*:*:*:*:* |
| autodesk | vault | >= 2025, < 2025.1.2 | cpe:2.3:a:autodesk:vault:*:*:*:*:*:*:*:* |