CVE-2025-1276 | DWG File Parsing Out-of-Bounds Write Vulnerability

A maliciously crafted DWG file, when parsed through certain Autodesk applications, can force an Out-of-Bounds Write vulnerability. A malicious actor may leverage this vulnerability to cause a crash, cause data corruption, or execute arbitrary code in the context of the current process.

Published: 2025-04-15 Last update: 2025-08-19 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2025-1276 is rated Moderate Risk (42.9/100): CVSS High severity, with low exploitation likelihood (EPSS 0.14%). Mandatory action: Review affected assets and schedule remediation.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2025-1276

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-05-27 0.18% 0.14% -0.04%
2 2026-05-26 0.06% 0.18% +0.12%
3 2026-02-09 0.06%

Full EPSS history (4 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2025-1276

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
7.8 3.1 HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H Click to expand
Attack vector (AV:L)
They already need access on the box, or another person has to do something wrong; it’s not a remote drive-by.
Attack complexity (AC:L)
Once they can reach the bug, pulling it off is straightforward—no weird race conditions or rare setup.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:R)
A real person has to do something—click, install, enable—otherwise it doesn’t land.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:H)
Serious risk that confidential data gets exposed in a big way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:H)
Could take the service down hard or make it unusable for people who depend on it.
1.8 5.9 [email protected]

Weakness enumeration for CVE-2025-1276

Affected software / configurations for CVE-2025-1276

Vendor Product Version Raw CPE
autodesk advance_steel >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
autodesk advance_steel >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
autodesk advance_steel >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*
autodesk autocad >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad:*:*:*:*:*:-:*:*
autodesk autocad >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad:*:*:*:*:*:-:*:*
autodesk autocad >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad:*:*:*:*:*:-:*:*
autodesk autocad_architecture >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
autodesk autocad_architecture >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
autodesk autocad_architecture >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*
autodesk autocad_electrical >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
autodesk autocad_electrical >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
autodesk autocad_electrical >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*
autodesk autocad_lt >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:-:*:*
autodesk autocad_lt >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:-:*:*
autodesk autocad_lt >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:-:*:*
autodesk autocad_map_3d >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
autodesk autocad_map_3d >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
autodesk autocad_map_3d >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*
autodesk autocad_mechanical >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
autodesk autocad_mechanical >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
autodesk autocad_mechanical >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*
autodesk autocad_mep >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
autodesk autocad_mep >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
autodesk autocad_mep >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*
autodesk autocad_plant_3d >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
autodesk autocad_plant_3d >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
autodesk autocad_plant_3d >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*
autodesk civil_3d >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
autodesk civil_3d >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
autodesk civil_3d >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*
autodesk dwg_trueview >= 2023, < 2023.1.7 cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*
autodesk dwg_trueview >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*
autodesk dwg_trueview >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:dwg_trueview:*:*:*:*:*:*:*:*
autodesk infrastructure_parts_editor >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:infrastructure_parts_editor:*:*:*:*:*:*:*:*
autodesk infrastructure_parts_editor >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:infrastructure_parts_editor:*:*:*:*:*:*:*:*
autodesk inventor >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:inventor:*:*:*:*:*:*:*:*
autodesk inventor >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:inventor:*:*:*:*:*:*:*:*
autodesk navisworks_manage >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:navisworks_manage:*:*:*:*:*:*:*:*
autodesk navisworks_manage >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:navisworks_manage:*:*:*:*:*:*:*:*
autodesk navisworks_simulate >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:navisworks_simulate:*:*:*:*:*:*:*:*
autodesk navisworks_simulate >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:navisworks_simulate:*:*:*:*:*:*:*:*
autodesk revit >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*
autodesk revit >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*
autodesk vault >= 2024, < 2024.1.7 cpe:2.3:a:autodesk:vault:*:*:*:*:*:*:*:*
autodesk vault >= 2025, < 2025.1.2 cpe:2.3:a:autodesk:vault:*:*:*:*:*:*:*:*

References for CVE-2025-1276

cvelogic Threat Intelligence