A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition. Successful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted.
Conclusion & alert: CVE-2025-29931 is rated Moderate Risk (55/100): CVSS Medium severity, with medium exploitation likelihood (EPSS 1.82%). Mandatory action: Review affected assets and schedule remediation.
Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.
EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).
| # | Date | Old EPSS score | New EPSS score | Delta (New - Old) |
|---|---|---|---|---|
| 1 | 2026-06-02 | 1.15% | 1.82% | +0.67% |
| 2 | 2026-05-31 | 1.04% | 1.15% | +0.11% |
| 3 | 2026-05-26 | — | 1.04% | — |
Full EPSS history (11 records total)
CVSS metrics for this CVE.
| Base score | Version | Severity | Vector | Exploitability | Impact | Score source |
|---|---|---|---|---|---|---|
| 6.3 | 4.0 | MEDIUM |
|
— | — | [email protected] |
| 3.7 | 3.1 | LOW |
|
2.2 | 1.4 | [email protected] |
| Vendor | Product | Version | Raw CPE |
|---|---|---|---|
| siemens | telecontrol_server_basic | < 3.1.2.2 | cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:* |
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/html/ssa-395348.html | Vendor Advisory |