CVE-2025-31929

A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.

Published: 2025-05-13 Last update: 2026-04-15 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2025-31929 is rated Low Risk (24.5/100): CVSS Medium severity, with low exploitation likelihood (EPSS 0.08%). Mandatory action: Monitor for updates and reassess as exploit intelligence or EPSS changes.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2025-31929

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-03-09 0.02% 0.08% +0.05%
2 2025-05-13 0.02%

Full EPSS history (2 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2025-31929

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
4.1 4.0 MEDIUM
CVSS:4.0/AV:P/AC:H/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Click to expand
Attack vector (AV:P)
Physical access is required.
Attack complexity (AC:H)
Exploitation depends on constrained or hard-to-reproduce conditions.
Attack requirements (AT:N)
No additional preconditions are required beyond normal reachability.
Privileges required (PR:N)
No privileges are required.
User interaction (UI:N)
No user interaction is required.
Vulnerable system confidentiality impact (VC:N)
No confidentiality impact on the vulnerable system.
Vulnerable system integrity impact (VI:H)
High integrity impact on the vulnerable system.
Vulnerable system availability impact (VA:N)
No availability impact on the vulnerable system.
Subsequent system confidentiality impact (SC:N)
No confidentiality impact on subsequent systems.
Subsequent system integrity impact (SI:N)
No integrity impact on subsequent systems.
Subsequent system availability impact (SA:N)
No availability impact on subsequent systems.
Exploit maturity (threat) (E:X)
Not defined: no reliable threat intelligence; scoring assumes the worst case (equivalent to Attacked).
Confidentiality requirement (CR:X)
Not defined: insufficient information; scoring treats this like High (worst case).
Integrity requirement (IR:X)
Not defined: insufficient information; scoring treats this like High (worst case).
Availability requirement (AR:X)
Not defined: insufficient information; scoring treats this like High (worst case).
Modified attack vector (MAV:X)
Not defined: scoring uses the Base Attack Vector (AV).
Modified attack complexity (MAC:X)
Not defined: scoring uses the Base Attack Complexity (AC).
Modified attack requirements (MAT:X)
Not defined: scoring uses the Base Attack Requirements (AT).
Modified privileges required (MPR:X)
Not defined: scoring uses the Base Privileges Required (PR).
Modified user interaction (MUI:X)
Not defined: scoring uses the Base User Interaction (UI).
Modified vulnerable system confidentiality impact (MVC:X)
Not defined: scoring uses the Base VC metric.
Modified vulnerable system integrity impact (MVI:X)
Not defined: scoring uses the Base VI metric.
Modified vulnerable system availability impact (MVA:X)
Not defined: scoring uses the Base VA metric.
Modified subsequent system confidentiality impact (MSC:X)
Not defined: scoring uses the Base SC metric.
Modified subsequent system integrity impact (MSI:X)
Not defined: scoring uses the Base SI metric.
Modified subsequent system availability impact (MSA:X)
Not defined: scoring uses the Base SA metric.
Safety (supplemental) (S:X)
Not evaluated.
Automatable (supplemental) (AU:X)
Not evaluated.
Recovery (supplemental) (R:X)
Not evaluated.
Value density (supplemental) (V:X)
Not evaluated.
Vulnerability response effort (supplemental) (RE:X)
Not evaluated.
Provider urgency (supplemental) (U:X)
Not evaluated.
[email protected]
4.2 3.1 MEDIUM
CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N Click to expand
Attack vector (AV:P)
Hands-on access—USB, keyboard, opening the case—not something you do purely over the wire.
Attack complexity (AC:H)
Even with access, the exploit needs extra luck, timing, or a fussy environment to actually work.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:N)
Nobody has to click “OK” or open a trap file; it can work without a victim helping.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:N)
Doesn’t really leak secrets in a meaningful way.
Integrity (I:H)
They could widely tamper with or forge data—trust in the data is badly hurt.
Availability (A:N)
Service keeps running; no real outage angle.
0.5 3.6 [email protected]

Weakness enumeration for CVE-2025-31929

Affected software / configurations for CVE-2025-31929

Vendor Product Version Raw CPE
No affected products in dataset.

References for CVE-2025-31929

cvelogic Threat Intelligence