Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Room Air Conditioners (for...

Description

Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Packaged Air Conditioners (for Japan and outside Japan); Refrigerators (for Japan); Heat Pump Water Heaters / HEMS-Compatible Adapters / Wireless LAN Adapters (for Japan); Bathroom Dryer / Heater / Ventilation Systems (for Japan); Adapters for Airflow Ventilation Systems, Heat Pump Chilled / Hot Water Systems, and Ventilation / Air-Conditioning System Air Resorts (for Japan); Lossnay Central Ventilation Systems (for Japan); Smart Switches for Ventilation Fans and Lossnay (for Japan); IH Cooking Heaters (for Japan); and Rice Cookers (for Japan) allows an attacker within Wi-Fi radio range of an affected product to access the affected product using a hard-coded SSID and password, thereby obtaining device data such as operation status, room set temperature, and room temperature; changing the air-conditioner or Wi-Fi settings; or causing Wi-Fi communication to enter a denial-of-service (DoS) condition.

Basic information

Type
unreviewed
Severity
high
Advisory on GitHub
Open advisory ↗
Repository advisory
Source code
Not specified
Published (advisory)
2026-06-17 18:35:59 UTC
Updated
2026-06-17 18:36:07 UTC
NVD published
2026-06-17

EPSS Score

Score Percentile
0.15% 4.59%

CVSS Scores

Base score Version Severity Vector
7.2 4.0
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X Click to expand
Attack vector (AV:A)
Attacker has to be on an adjacent/local network segment.
Attack complexity (AC:L)
Exploitation conditions are straightforward and stable.
Attack requirements (AT:N)
No additional preconditions are required beyond normal reachability.
Privileges required (PR:N)
No privileges are required.
User interaction (UI:N)
No user interaction is required.
Vulnerable system confidentiality impact (VC:H)
High confidentiality impact on the vulnerable system.
Vulnerable system integrity impact (VI:L)
Limited integrity impact on the vulnerable system.
Vulnerable system availability impact (VA:L)
Limited availability impact on the vulnerable system.
Subsequent system confidentiality impact (SC:N)
No confidentiality impact on subsequent systems.
Subsequent system integrity impact (SI:N)
No integrity impact on subsequent systems.
Subsequent system availability impact (SA:N)
No availability impact on subsequent systems.
Exploit maturity (threat) (E:X)
Not defined: no reliable threat intelligence; scoring assumes the worst case (equivalent to Attacked).
Confidentiality requirement (CR:X)
Not defined: insufficient information; scoring treats this like High (worst case).
Integrity requirement (IR:X)
Not defined: insufficient information; scoring treats this like High (worst case).
Availability requirement (AR:X)
Not defined: insufficient information; scoring treats this like High (worst case).
Modified attack vector (MAV:X)
Not defined: scoring uses the Base Attack Vector (AV).
Modified attack complexity (MAC:X)
Not defined: scoring uses the Base Attack Complexity (AC).
Modified attack requirements (MAT:X)
Not defined: scoring uses the Base Attack Requirements (AT).
Modified privileges required (MPR:X)
Not defined: scoring uses the Base Privileges Required (PR).
Modified user interaction (MUI:X)
Not defined: scoring uses the Base User Interaction (UI).
Modified vulnerable system confidentiality impact (MVC:X)
Not defined: scoring uses the Base VC metric.
Modified vulnerable system integrity impact (MVI:X)
Not defined: scoring uses the Base VI metric.
Modified vulnerable system availability impact (MVA:X)
Not defined: scoring uses the Base VA metric.
Modified subsequent system confidentiality impact (MSC:X)
Not defined: scoring uses the Base SC metric.
Modified subsequent system integrity impact (MSI:X)
Not defined: scoring uses the Base SI metric.
Modified subsequent system availability impact (MSA:X)
Not defined: scoring uses the Base SA metric.
Safety (supplemental) (S:X)
Not evaluated.
Automatable (supplemental) (AU:X)
Not evaluated.
Recovery (supplemental) (R:X)
Not evaluated.
Value density (supplemental) (V:X)
Not evaluated.
Vulnerability response effort (supplemental) (RE:X)
Not evaluated.
Provider urgency (supplemental) (U:X)
Not evaluated.

Identifiers

CWEs

CWE id Name
CWE-798 Use of Hard-coded Credentials

References

cvelogic Threat Intelligence