A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
総合評価: CVE-2019-6576 は中リスク(53.5/100)。CVSS 深刻度は中。悪用される可能性が高い(EPSS 1.74%、75 パーセンタイル) 根拠: 直近 1 日で EPSS が +1.35% 上昇。悪用への関心が高まっている可能性があります。 推奨対応: 影響資産を整理し、修補計画に組み込んでください。
リスクは変動します。再評価に基づき、本ページの表示内容を更新しています。
EPSS は日次で悪用されやすさの相対度合いを推定します。パーセンタイルは採点済み CVE の中での相対位置(高いほど相対的に深刻)を示します。
| # | 日付 | 旧 EPSS スコア | 新 EPSS スコア | Δ(新 − 旧) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 0.39% | 1.74% | +1.35% |
| 2 | 2025-03-30 | 0.75% | 0.39% | -0.36% |
| 3 | 2025-03-29 | — | 0.75% | — |
EPSS の全履歴 (全 9 件)
この CVE の CVSS 指標。
| ベーススコア | バージョン | 深刻度 | ベクトル | 悪用しやすさ | 影響 | スコアの出典 |
|---|---|---|---|---|---|---|
| 6.5 | 3.1 | MEDIUM |
|
2.8 | 3.6 | 134c704f-9b21-4f2e-91b3-4a467353bcc0 |
| 7.5 | 3.0 | HIGH |
|
3.9 | 3.6 | [email protected] |
| 5.0 | 2.0 | MEDIUM |
|
10.0 | 2.9 | [email protected] |
| ベンダー | 製品 | バージョン | 生の CPE |
|---|---|---|---|
| siemens | simatic_hmi_comfort_panels_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_comfort_outdoor_panels_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp400f_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp700_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp700f_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp900_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_ktp_mobile_panels_ktp900f_firmware | < 15.1 | cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_wincc_\(tia_portal\) | < 15.1 | cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):*:*:*:*:*:*:*:* |
| siemens | simatic_wincc_runtime | < 15.1 | cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:* |
| siemens | simatic_wincc_runtime | < 15.1 | cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:* |
| siemens | simatic_hmi_tp_firmware | — | cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_mp_firmware | — | cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:* |
| siemens | simatic_hmi_op_firmware | — | cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:* |