Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
総合評価: CVE-2021-20587 は中リスク(55.9/100)。CVSS 深刻度は高。悪用される可能性が高い(EPSS 3.66%、88 パーセンタイル) 推奨対応: 影響資産を整理し、修補計画に組み込んでください。
リスクは変動します。再評価に基づき、本ページの表示内容を更新しています。
EPSS は日次で悪用されやすさの相対度合いを推定します。パーセンタイルは採点済み CVE の中での相対位置(高いほど相対的に深刻)を示します。
| # | 日付 | 旧 EPSS スコア | 新 EPSS スコア | Δ(新 − 旧) |
|---|---|---|---|---|
| 1 | 2026-06-15 | 11.75% | 3.66% | -8.09% |
| 2 | 2026-02-21 | 9.01% | 11.75% | +2.75% |
| 3 | 2025-11-24 | — | 9.01% | — |
EPSS の全履歴 (全 23 件)
この CVE の CVSS 指標。
| ベーススコア | バージョン | 深刻度 | ベクトル | 悪用しやすさ | 影響 | スコアの出典 |
|---|---|---|---|---|---|---|
| 7.5 | 3.1 | HIGH |
|
3.9 | 3.6 | [email protected] |
| 9.8 | 3.1 | CRITICAL |
|
3.9 | 5.9 | [email protected] |
| 7.5 | 2.0 | HIGH |
|
10.0 | 6.4 | [email protected] |
| ベンダー | 製品 | バージョン | 生の CPE |
|---|---|---|---|
| mitsubishielectric | c_controller_module_setting_and_monitoring_tool | — | cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:* |
| mitsubishielectric | cpu_module_logging_configuration_tool | <= 1.112r | cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:* |
| mitsubishielectric | cw_configurator | <= 1.011m | cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:* |
| mitsubishielectric | data_transfer | <= 3.44w | cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:* |
| mitsubishielectric | ezsocket | — | cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:* |
| mitsubishielectric | fr_configurator | — | cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:* |
| mitsubishielectric | fr_configurator_sw3 | — | cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:* |
| mitsubishielectric | fr_configurator2 | <= 1.24a | cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:* |
| mitsubishielectric | gt_designer3 | <= 1.250l | cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:* |
| mitsubishielectric | gt_softgot1000 | <= 3.245f | cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:* |
| mitsubishielectric | gt_softgot2000 | <= 1.250l | cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_configurator-dp | <= 7.14q | cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_configurator-qp | — | cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_developer | <= 8.506c | cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_explorer | — | cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_iec_developer | — | cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_logviewer | <= 1.115u | cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_remoteservice-i | — | cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_works2 | <= 1.597x | cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:* |
| mitsubishielectric | gx_works3 | <= 1.070y | cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:* |
| mitsubishielectric | iq_monozukuri_andon | — | cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:* |
| mitsubishielectric | iq_monozukuri_process_remote_monitoring | — | cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:* |
| mitsubishielectric | m_commdtm-hart | — | cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:* |
| mitsubishielectric | m_commdtm-io-link | — | cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:* |
| mitsubishielectric | melfa-works | <= 4.4 | cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:* |
| mitsubishielectric | melsec_wincpu_setting_utility | — | cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:* |
| mitsubishielectric | melsoft_em_software_development_kit | — | cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:* |
| mitsubishielectric | melsoft_navigator | <= 2.74c | cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:* |
| mitsubishielectric | mh11_settingtool_version2 | <= 2.004e | cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:* |
| mitsubishielectric | mi_configurator | — | cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:* |
| mitsubishielectric | mt_works2 | <= 1.167z | cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:* |
| mitsubishielectric | mx_component | <= 5.001b | cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:* |
| mitsubishielectric | network_interface_board_cc-link | — | cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:* |
| mitsubishielectric | network_interface_board_cc_ie_control_utility | — | cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:* |
| mitsubishielectric | network_interface_board_cc_ie_field_utility | — | cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:* |
| mitsubishielectric | network_interface_board_mneth_utility | — | cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:* |
| mitsubishielectric | px_developer | <= 1.53f | cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:* |
| mitsubishielectric | rt_toolbox2 | <= 3.73b | cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:* |
| mitsubishielectric | rt_toolbox3 | <= 1.82l | cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:* |
| mitsubishielectric | setting\/monitoring_tools_for_the_c_controller_module | — | cpe:2.3:a:mitsubishielectric:setting\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:* |
| mitsubishielectric | slmp_data_collector | <= 1.04e | cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:* |
| URL | タグ |
|---|---|
| https://jvn.jp/vu/JVNVU92330101 | |
| https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02 | |
| https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2020-021_en.pdf | |
| https://jvn.jp/vu/JVNVU92330101/index.html | Third Party Advisory |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 | Third Party Advisory US Government Resource |
| https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | Vendor Advisory |