CVE-2022-0715

A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

公開: 2022-03-09 最終更新: 2026-06-17 Assigner: [email protected] ソース: [email protected]

総合評価: CVE-2022-0715 は高リスク(73.4/100)。CVSS 深刻度は重大。悪用される可能性が高い(EPSS 5.80%、92 パーセンタイル) 根拠: EPSS 上、短期間での悪用可能性は高い水準です。 直近 1 日で EPSS が +4.77% 上昇。悪用への関心が高まっている可能性があります。 推奨対応: 悪用可能性が高いため、影響範囲の確認と修補の優先付けを推奨します。

リスクは変動します。再評価に基づき、本ページの表示内容を更新しています。

CVE-2022-0715 の EPSS(Exploit Prediction Scoring System)スコア

EPSS は日次で悪用されやすさの相対度合いを推定します。パーセンタイルは採点済み CVE の中での相対位置(高いほど相対的に深刻)を示します。

# 日付 旧 EPSS スコア 新 EPSS スコア Δ(新 − 旧)
1 2026-06-15 1.03% 5.80% +4.77%
2 2026-05-30 1.08% 1.03% -0.05%
3 2026-03-17 1.08%

EPSS の全履歴 (全 15 件)

CVE-2022-0715 の CVSS(Common Vulnerability Scoring System)指標

この CVE の CVSS 指標。

ベーススコア バージョン 深刻度 ベクトル 悪用しやすさ 影響 スコアの出典
9.1 3.1 CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H クリックして展開
攻撃ベクター (AV:N)
インターネットなど、ルーティングされたネットワーク越しに遠隔から悪用しうる。端末の前にいる必要はない。
攻撃の複雑さ (AC:L)
攻撃者が条件を満たせば、レース条件や珍しい構成に依存せずに再現しやすい。
必要な権限 (PR:N)
事前のログインや昇格は不要で、匿名アクセスのまま踏み台にしうる。
ユーザーの関与 (UI:N)
メールのリンクを開く、マクロを有効にするなど、被害者の協力がなくても成立しうる。
スコープ (S:U)
影響は脆弱コンポーネントと同一のセキュリティ権限・信頼境界の内側に収まる。
機密性への影響 (C:N)
機微情報の漏えいは想定しにくい。
完全性への影響 (I:H)
権限の奪取や広範なログ改竄など、システムの信頼根拠を揺るがす改ざんが現実的。
可用性への影響 (A:H)
長時間のサービス停止、データ損壊による復旧不能に近い状態など、利用者に著しい不便を与えうる。
3.9 5.2 [email protected]
8.9 3.1 HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H クリックして展開
攻撃ベクター (AV:N)
インターネットなど、ルーティングされたネットワーク越しに遠隔から悪用しうる。端末の前にいる必要はない。
攻撃の複雑さ (AC:H)
到達できても、タイミング・負荷・周辺設定など、揃わないと成功しない局面が多い。
必要な権限 (PR:N)
事前のログインや昇格は不要で、匿名アクセスのまま踏み台にしうる。
ユーザーの関与 (UI:N)
メールのリンクを開く、マクロを有効にするなど、被害者の協力がなくても成立しうる。
スコープ (S:C)
脆弱箇所を足がかりに、別コンポーネントや別権限域まで影響が広がりうる。
機密性への影響 (C:L)
一部のデータや属性が漏えいしうるが、全件一括流出といった規模には至らない。
完全性への影響 (I:H)
権限の奪取や広範なログ改竄など、システムの信頼根拠を揺るがす改ざんが現実的。
可用性への影響 (A:H)
長時間のサービス停止、データ損壊による復旧不能に近い状態など、利用者に著しい不便を与えうる。
2.2 6.0 134c704f-9b21-4f2e-91b3-4a467353bcc0
6.4 2.0 MEDIUM
AV:N/AC:L/Au:N/C:N/I:P/A:P クリックして展開
アクセス経路 (AV:N)
ルーティング可能なネットワーク越しに、遠隔から到達・悪用しうる。
アクセスの複雑さ (AC:L)
手順が短く、再現性が高い。
認証 (AU:N)
認証を経ずに攻撃を完結できる。
機密性への影響 (C:N)
機密性は損なわれない。
完全性への影響 (I:P)
完全性は部分的に損なわれる。
可用性への影響 (A:P)
可用性は部分的に損なわれる。
10.0 4.9 [email protected]

CVE-2022-0715 の弱点分類(列挙)

CVE-2022-0715 の GitHub Security Advisory

GHSA-fxwp-hqgp-45qg · 深刻度: critical — A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to...

CVE-2022-0715 の影響を受けるソフトウェア/構成

ベンダー 製品 バージョン 生の CPE
schneider-electric smt_series_1015_ups_firmware <= 04.5 cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smc_series_1018_ups_firmware <= 04.2 cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smtl_series_1026_ups_firmware <= 02.9 cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric scl_series_1029_ups_firmware <= 02.5 cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric scl_series_1030_ups_firmware <= 02.5 cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric scl_series_1036_ups_firmware <= 02.5 cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric scl_series_1037_ups_firmware <= 03.1 cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smx_series_1031_ups_firmware <= 03.1 cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smt_series_18_ups_firmware <= 09.8 cpe:2.3:o:schneider-electric:smt_series_18_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smt_series_1040_ups_firmware <= 01.2 cpe:2.3:o:schneider-electric:smt_series_1040_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smt_series_1031_ups_firmware <= 03.1 cpe:2.3:o:schneider-electric:smt_series_1031_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smc_series_1005_ups_firmware <= 14.1 cpe:2.3:o:schneider-electric:smc_series_1005_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smc_series_1007_ups_firmware <= 11.0 cpe:2.3:o:schneider-electric:smc_series_1007_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smc_series_1041_ups_firmware <= 01.1 cpe:2.3:o:schneider-electric:smc_series_1041_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smx_series_20_ups_firmware <= 10.2 cpe:2.3:o:schneider-electric:smx_series_20_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric smx_series_23_ups_firmware <= 07.0 cpe:2.3:o:schneider-electric:smx_series_23_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1010_ups_firmware <= 08.3 cpe:2.3:o:schneider-electric:srt_series_1010_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1019_ups_firmware <= 08.3 cpe:2.3:o:schneider-electric:srt_series_1019_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1025_ups_firmware <= 08.3 cpe:2.3:o:schneider-electric:srt_series_1025_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1020_ups_firmware <= 10.4 cpe:2.3:o:schneider-electric:srt_series_1020_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1021_ups_firmware <= 12.2 cpe:2.3:o:schneider-electric:srt_series_1021_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1001_ups_firmware <= 05.1 cpe:2.3:o:schneider-electric:srt_series_1001_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1013_ups_firmware <= 05.1 cpe:2.3:o:schneider-electric:srt_series_1013_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1002_ups_firmware <= a05.2 cpe:2.3:o:schneider-electric:srt_series_1002_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srt_series_1014_ups_firmware <= a05.2 cpe:2.3:o:schneider-electric:srt_series_1014_ups_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl1000rmxli_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl1000rmxli_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl1000rmxli-nc_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl1000rmxli-nc_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl1500rmxli-nc_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl1500rmxli-nc_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl1500rmxli_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl1500rmxli_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl2200rmxli_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl2200rmxli_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl2200rmxli-nc_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl2200rmxli-nc_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl3000rmxli-nc_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl3000rmxli-nc_firmware:*:*:*:*:*:*:*:*
schneider-electric srtl3000rmxli_firmware <= 01.0 cpe:2.3:o:schneider-electric:srtl3000rmxli_firmware:*:*:*:*:*:*:*:*

CVE-2022-0715 の参考情報

cvelogic Threat Intelligence