7t CVE 脆弱性と CVE 一覧(12)

製品(CPE): — CVE 件数: 12

7t 脆弱性概要

7t 関連製品全体の CVE とセキュリティ脆弱性情報を集約し、CVSS、EPSS、公開日、脆弱性情報データを掲載しています。

公開された問題は バッファオーバーフロー、パス処理の欠陥, and vendor risk cross-site scripting に関連することが多く、vendor surface software deployment and vendor surface production workloads の文脈で vendor impact memory corruption and ファイル上書き などの暴露リスクを伴う場合があります。

掲載データは公開脆弱性情報とセキュリティ公告に基づき、過去の暴露面と修補優先度の評価に利用できます。

脆弱性分布の推移(直近24か月)

表示中 112 / 12 CVE 件数
«« 先頭 « 前へ 1 / 1 次へ »
CVE 概要 ソース CVSS 最大値 EPSS(%) 公開 更新
CVE-2012-0223 Untrusted search path vulnerability in 7-Technologies (7T) TERMIS 2.10 and earlier allows local users to gain privileges via a Trojan horse DLL in the current working directory, a different vulnerability than CVE-2012-0224. [email protected] 9.3 0.40% 2012-02-22 2026-04-29
CVE-2012-0224 Untrusted search path vulnerability in 7-Technologies (7T) AQUIS 1.5 and earlier allows local users to gain privileges via a Trojan horse DLL in the current working directory, a different vulnerability than CVE-2012-0223. [email protected] 9.3 0.40% 2012-02-21 2026-04-29
CVE-2011-4053 Untrusted search path vulnerability in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) before 9.0.0.11291 allows local users to gain privileges via a Trojan horse DLL in the current working directory. [email protected] 9.3 0.40% 2012-01-19 2026-04-29
CVE-2011-4537 Multiple buffer overflows in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11355 and earlier allow remote attackers to execute arbitrary code or cause a denial of service via a crafted packet to TCP port (1) 12397 or (2) 12399. [email protected] 7.5 20.17% 2011-12-27 2026-04-29
CVE-2011-4050 Buffer overflow in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11200 allows remote attackers to cause a denial of service via a crafted packet to TCP port 12401. [email protected] 5.0 77.32% 2011-12-27 2026-04-29
CVE-2011-3339 Cross-site scripting (XSS) vulnerability in the Admin Control Center in Sentinel HASP Run-time Environment 5.95 and earlier in SafeNet Sentinel HASP (formerly Aladdin HASP SRM) run-time installer before 6.x and SDK before 5.11, as used in 7 Technologies (7T) IGSS 7 and other products, when Firefox 2.0 is used, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors that trigger write access to a configuration file. [email protected] 4.3 0.89% 2011-12-17 2026-04-29
CVE-2011-2959 Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet to TCP port 22202. [email protected] 10.0 12.29% 2011-07-29 2026-04-29
CVE-2011-2214 Unspecified vulnerability in the Open Database Connectivity (ODBC) component in 7T Interactive Graphical SCADA System (IGSS) before 9.0.0.11143 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 20222, which triggers memory corruption related to an "invalid structure being used." [email protected] 10.0 12.97% 2011-05-31 2026-04-29
CVE-2011-1568 Format string vulnerability in the logText function in shmemmgr9.dll in IGSSdataServer.exe 9.00.00.11074, and 9.00.00.11063 and earlier, in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote attackers to cause a denial of service and possibly execute arbitrary code, as demonstrated using the RMS Reports Delete command, related to the logging of messages to GSST.LOG. NOTE: some of these details are obtained from third party information. [email protected] 10.0 44.21% 2011-04-05 2026-04-29
CVE-2011-1567 Multiple stack-based buffer overflows in IGSSdataServer.exe 9.00.00.11063 and earlier in 7-Technologies Interactive Graphical SCADA System (IGSS) allow remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via crafted (1) ListAll, (2) Write File, (3) ReadFile, (4) Delete, (5) RenameFile, and (6) FileInfo commands in an 0xd opcode; (7) the Add, (8) ReadFile, (9) Write File, (10) Rename, (11) Delete, and (12) Add commands in an RMS report templates (0x7) opcode; [email protected] 10.0 81.11% 2011-04-05 2026-04-29
CVE-2011-1566 Directory traversal vulnerability in dc.exe 9.00.00.11059 and earlier in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote attackers to execute arbitrary programs via ..\ (dot dot backslash) sequences in opcodes (1) 0xa and (2) 0x17 to TCP port 12397. [email protected] 10.0 77.66% 2011-04-05 2026-04-29
CVE-2011-1565 Directory traversal vulnerability in IGSSdataServer.exe 9.00.00.11063 and earlier in 7-Technologies Interactive Graphical SCADA System (IGSS) allows remote attackers to (1) read (opcode 0x3) or (2) create or write (opcode 0x2) arbitrary files via ..\ (dot dot backslash) sequences to TCP port 12401. [email protected] 10.0 67.89% 2011-04-05 2026-04-29
«« 先頭 « 前へ 1 / 1 次へ »