garrett 関連製品全体の CVE とセキュリティ脆弱性情報を集約し、CVSS、EPSS、公開日、脆弱性情報データを掲載しています。
一般的な弱点パターンには パス処理の欠陥、バッファオーバーフロー, and vendor risk memory corruption があり、vendor surface software deployment and vendor surface production workloads の利用場面で vendor impact memory corruption、アプリケーションクラッシュ, and ファイル上書き などのリスクが生じる可能性があります。
掲載データは公開脆弱性情報とセキュリティ公告に基づき、過去の暴露面と修補優先度の評価に利用できます。
| CVE | 概要 | ソース | CVSS 最大値 | EPSS(%) | 公開 | 更新 |
|---|---|---|---|---|---|---|
| CVE-2021-21909 | Specially-crafted command line arguments can lead to arbitrary file deletion in the del .cnt|.log file delete command. An attacker can provide malicious inputs to trigger this vulnerability | [email protected] | 8.1 | 0.48% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21908 | Specially-crafted command line arguments can lead to arbitrary file deletion. The handle_delete function does not attempt to sanitize or otherwise validate the contents of the [file] parameter (passed to the function as argv[1]), allowing an authenticated attacker to supply directory traversal primitives and delete semi-arbitrary files. | [email protected] | 6.5 | 1.37% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21907 | A directory traversal vulnerability exists in the CMA CLI getenv command functionality of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted command line argument can lead to local file inclusion. An attacker can provide malicious input to trigger this vulnerability. | [email protected] | 4.9 | 0.33% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21906 | Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to | [email protected] | 7.2 | 0.38% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21905 | Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device. | [email protected] | 7.2 | 0.38% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21904 | A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors’ iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability | [email protected] | 7.2 | 2.06% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21903 | A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability. | [email protected] | 9.8 | 0.18% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21902 | An authentication bypass vulnerability exists in the CMA run_server_6877 functionality of Garrett Metal Detectors iC Module CMA Version 5.0. A properly-timed network connection can lead to authentication bypass via session hijacking. An attacker can send a sequence of requests to trigger this vulnerability. | [email protected] | 8.1 | 0.44% | 2021-12-22 | 2024-11-21 |
| CVE-2021-21901 | A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to memcpy. An attacker can send a malicious packet to trigger this vulnerability. | [email protected] | 8.8 | 0.16% | 2021-12-22 | 2024-11-21 |