ishekar 関連製品全体の CVE とセキュリティ脆弱性情報を集約し、CVSS、EPSS、公開日、脆弱性情報データを掲載しています。
過去の問題は主に バッファオーバーフロー and パス処理の欠陥 などに関し、一部は アプリケーションクラッシュ を招き、vendor surface software deployment and vendor surface production workloads 関連の場面に影響します。
掲載データは公開脆弱性情報とセキュリティ公告に基づき、過去の暴露面と修補優先度の評価に利用できます。
| CVE | 概要 | ソース | CVSS 最大値 | EPSS(%) | 公開 | 更新 |
|---|---|---|---|---|---|---|
| CVE-2017-10724 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breac | [email protected] | 8.8 | 1.85% | 2019-06-17 | 2024-11-21 |
| CVE-2017-10723 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breac | [email protected] | 8.8 | 1.85% | 2019-06-17 | 2024-11-21 |
| CVE-2017-10722 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is installed on the device and an attacker who can provide the right payload can execute code on the user's system directly. Any breach of this system can allow an attacker to get access to all the data that th | [email protected] | 7.8 | 0.14% | 2019-06-17 | 2024-11-21 |
| CVE-2017-10721 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has Telnet functionality enabled by default. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed a | [email protected] | 6.5 | 0.40% | 2019-06-17 | 2024-11-21 |
| CVE-2017-10720 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi name. This application is installed on the device and an attacker who can provide the right payload can execute code on the user's system directly. Any breach of this system can allow an attacker to get access to all the data that the us | [email protected] | 7.8 | 0.14% | 2019-06-17 | 2024-11-21 |
| CVE-2017-10719 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has default Wi-Fi credentials that are exactly the same for every device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker | [email protected] | 6.5 | 1.12% | 2019-06-17 | 2024-11-21 |
| CVE-2017-10718 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that any malicious user connecting to the device can change the default SSID and password thereby denying the owner an access to his/her own device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being | [email protected] | 6.5 | 0.52% | 2019-06-17 | 2024-11-21 |