CVE-2018-15480 An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously regi [email protected] 8.8 0.55% 2018-08-30 2024-11-21
CVE-2018-15479 An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. Devices did not authenticate themselves to the cloud in device to cloud communication. This lack of device authentication allowed an attacker to impersonate any device by guessing or learning their MAC address. [email protected] 6.5 0.19% 2018-08-30 2024-11-21
CVE-2018-15478 An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based on an activation code derived from the device MAC address. By guessing valid MAC addresses or using MAC addresses printed on devices in shops and reverse engineering the protocol, an attacker would have b [email protected] 8.1 0.34% 2018-08-30 2024-11-21
CVE-2018-15477 myStrom WiFi Switch V1 devices before 2.66 did not sanitize a parameter received from the cloud that was used in an OS command. Malicious servers were able to run operating system commands on the device. [email protected] 9.8 0.38% 2018-08-30 2024-11-21
CVE-2018-15476 An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The SSL/TLS server certificate in the device to cloud communication was not verified by the device. As a result, an attacker in control of the network traffic of a device could have taken control of a device by intercepting and modifying commands issued from the server t [email protected] 8.1 0.14% 2018-08-30 2024-11-21