schneider_electric CVE 脆弱性と CVE 一覧(6)

製品(CPE): — CVE 件数: 6

schneider_electric 脆弱性概要

schneider_electric 関連製品全体の CVE とセキュリティ脆弱性情報を集約し、CVSS、EPSS、公開日、脆弱性情報データを掲載しています。

一般的な弱点パターンには バッファオーバーフロー、vendor risk cross-site scripting, and vendor risk memory corruption があり、vendor surface software deployment の利用場面で アプリケーションクラッシュ、vendor impact memory corruption, and vendor impact session compromise などのリスクが生じる可能性があります。

掲載データは公開脆弱性情報とセキュリティ公告に基づき、過去の暴露面と修補優先度の評価に利用できます。

脆弱性分布の推移(直近24か月)

表示中 16 / 6 CVE 件数
«« 先頭 « 前へ 1 / 1 次へ »
CVE 概要 ソース CVSS 最大値 EPSS(%) 公開 更新
CVE-2017-5157 An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code. [email protected] 6.1 1.46% 2017-02-13 2026-06-16
CVE-2014-9188 Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers. [email protected] 10.0 6.12% 2014-12-27 2026-06-16
CVE-2014-8514 Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. [email protected] 7.5 4.00% 2014-12-27 2026-06-16
CVE-2014-8513 Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. [email protected] 7.5 2.95% 2014-12-27 2026-06-16
CVE-2014-8512 Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers. [email protected] 7.5 3.93% 2014-12-27 2026-06-16
CVE-2013-0662 Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. [email protected] 9.3 22.29% 2014-04-01 2026-06-16
«« 先頭 « 前へ 1 / 1 次へ »
cvelogic Threat Intelligence