CVE Summary Source Max CVSS EPSS % Published Updated
CVE-2024-41716 Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product's project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them. [email protected] 8.1 0.45% 2024-09-04 2025-03-13
CVE-2021-37401 An attacker may obtain the user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the PLC user program may be uploaded, altered, and/or downloaded. [email protected] 9.8 1.34% 2021-12-28 2024-11-21
CVE-2021-37400 An attacker may obtain the user credentials from the communication between the PLC and the software. As a result, the PLC user program may be uploaded, altered, and/or downloaded. [email protected] 9.8 1.34% 2021-12-28 2024-11-21
CVE-2021-20827 Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the attacker may access the PLC Web server and hijack the PLC, [email protected] 7.5 0.59% 2021-12-24 2024-11-21
CVE-2021-20826 Unprotected transport of credentials vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from the communication between the PLC and the software. As a result, the complete access privileges to the PLC Web server may be obtained, an [email protected] 7.6 0.39% 2021-12-24 2024-11-21