ni flexlogger CVE Vulnerabilities (5)

CVEs: 5 CPE versions: View versions table

Summary

This page lists publicly disclosed CVE vulnerabilities affecting ni flexlogger (linked via NVD CPE). Each row includes severity scores, summaries, and publication dates to help identify and analyze security issues.

Showing 15 of 5 CVEs
«« First « Prev Page 1 / 1 Next »
CVE Summary Source Max CVSS EPSS % Published Updated
CVE-2025-2449 NI FlexLogger usiReg URI File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of NI FlexLogger. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of URI files by the usiReg component. The issue results from the lack of proper validation of a user-supplied path [email protected] 8.8 30.78% 2025-03-18 2026-06-17
CVE-2024-6122 An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may result in information disclosure via local access. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service. [email protected] 5.5 0.24% 2024-07-22 2026-06-17
CVE-2024-6121 An out-of-date version of Redis shipped with NI SystemLink Server is susceptible to multiple vulnerabilities, including CVE-2022-24834. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service. [email protected] 7.8 0.27% 2024-07-22 2026-06-17
CVE-2023-5136 An incorrect permission assignment in the TopoGrafix DataPlugin for GPX could result in information disclosure. An attacker could exploit this vulnerability by getting a user to open a specially crafted data file. [email protected] 5.5 0.25% 2023-11-08 2026-06-17
CVE-2022-27237 There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later. [email protected] 6.1 0.53% 2022-04-21 2026-06-17
«« First « Prev Page 1 / 1 Next »
cvelogic Threat Intelligence