tenda i6_firmware CVE Vulnerabilities (7)

CVEs: 7 CPE versions: View versions table

Summary

This page lists publicly disclosed CVE vulnerabilities affecting tenda i6_firmware (linked via NVD CPE). Each row includes severity scores, summaries, and publication dates to help identify and analyze security issues.

Showing 17 of 7 CVEs
«« First « Prev Page 1 / 1 Next »
CVE Summary Source Max CVSS EPSS % Published Updated
CVE-2026-6024 A vulnerability was determined in Tenda i6 1.0.0.7(2204). Affected by this issue is the function R7WebsSecurityHandlerfunction of the component HTTP Handler. This manipulation causes path traversal. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. [email protected] 5.5 0.69% 2026-04-10 2026-06-17
CVE-2024-0993 A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure [email protected] 7.2 1.66% 2024-01-28 2026-06-17
CVE-2024-0992 A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond [email protected] 7.2 1.66% 2024-01-28 2026-06-17
CVE-2024-0991 A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond i [email protected] 7.2 1.66% 2024-01-28 2026-06-17
CVE-2024-0990 A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but d [email protected] 7.2 1.66% 2024-01-28 2026-06-17
CVE-2023-48964 Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet. [email protected] 7.5 0.77% 2023-11-30 2026-06-17
CVE-2023-48963 Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget. [email protected] 7.5 0.77% 2023-11-30 2026-06-17