ribboncommunications CVE Vulnerabilities & CVE List (4)

Products (CPE): — CVEs: 4

ribboncommunications vulnerability overview

Aggregates CVE and security vulnerability intelligence across all ribboncommunications-related products, including CVSS, EPSS, publication dates, and vulnerability intelligence data.

Disclosed issues often relate to vendor risk path handling; exposure may include vendor impact file overwrite in vendor surface software deployment and vendor surface production workloads contexts.

Vulnerability distribution trend (last 24 months)

Showing 14 of 4 CVEs
«« First « Prev Page 1 / 1 Next »
CVE Summary Source Max CVSS EPSS % Published Updated
CVE-2018-11543 A Local File Inclusion (LFI) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the downloading of arbitrary files via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140. [email protected] 7.5 1.61% 2018-07-09 2024-11-21
CVE-2018-11542 A Remote Command Execution (RCE) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the execution of arbitrary commands via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140. [email protected] 9.8 3.44% 2018-07-09 2024-11-21
CVE-2018-11541 A root privilege escalation vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows unauthorised access to privileged content via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140. [email protected] 9.8 1.75% 2018-07-09 2024-11-21
CVE-2017-6079 The HTTP web-management application on Edgewater Networks Edgemarc appliances has a hidden page that allows for user-defined commands such as specific iptables routes, etc., to be set. You can use this page as a web shell essentially to execute commands, though you get no feedback client-side from the web application: if the command is valid, it executes. An example is the wget command. The page that allows this has been confirmed in firmware as old as 2006. [email protected] 9.8 46.85% 2017-05-16 2026-05-13
«« First « Prev Page 1 / 1 Next »
cvelogic Threat Intelligence