Aggregating NVD, CVE, and multi-source threat feeds, this list provides deep analysis of high-risk threats such as RCE. By integrating CVSS and EPSS models, the system dynamically tracks Exp (Exploit) resources and PoC availability to accurately assess Exploitability. Combined with official Patches and remediation strategies, it helps prioritize Vulnerability Management workflows, significantly shortening response cycles and securing your critical assets.
Assigner (CNA / source):[email protected] Remove this filter
| CVE | Description | Max CVSS | EPSS % | Published | Updated |
|---|---|---|---|---|---|
| CVE-2019-19101 | A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable unauthenticated users to perform MITM attacks via the B&R upgrade server. | 6.5 | 0.52% | 2020-04-28 | 2026-06-16 |
| CVE-2019-19102 | A directory traversal vulnerability in SharpZipLib used in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x and 4.2.x allow unauthenticated users to write to certain local directories. The vulnerability is also known as zip slip. | 5.5 | 1.25% | 2020-04-28 | 2026-06-16 |
| CVE-2020-8482 | Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data | 7.8 | 0.32% | 2020-05-29 | 2026-06-16 |
| CVE-2020-11641 | A local file inclusion vulnerability in B&R SiteManager versions <9.2.620236042 allows authenticated users to read sensitive files from SiteManager instances. | 7.7 | 1.21% | 2020-10-15 | 2026-06-16 |
| CVE-2020-11642 | The local file inclusion vulnerability present in B&R SiteManager versions <9.2.620236042 allows authenticated users to impact availability of SiteManager instances. | 7.7 | 1.28% | 2020-10-15 | 2026-06-16 |
| CVE-2020-11643 | An information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains. | 6.5 | 1.27% | 2020-10-15 | 2026-06-16 |
| CVE-2020-11644 | The information disclosure vulnerability present in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to generate fake audit log messages. | 6.5 | 1.18% | 2020-10-15 | 2026-06-16 |
| CVE-2020-11645 | A denial of service vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to limit availability of GateManager instances. | 6.5 | 1.33% | 2020-10-15 | 2026-06-16 |
| CVE-2020-11646 | A log information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view log information reserved for other users. | 4.3 | 1.00% | 2020-10-15 | 2026-06-16 |
| CVE-2020-11637 | A memory leak in the TFTP service in B&R Automation Runtime versions <N4.26, <N4.34, <F4.45, <E4.53, <D4.63, <A4.73 and prior could allow an unauthenticated attacker with network access to cause a denial of service (DoS) condition. | 5.8 | 1.08% | 2020-10-15 | 2026-06-16 |
| CVE-2020-24673 | In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability. | 9.8 | 1.08% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24674 | In S+ Operations and S+ Historian, not all client commands correctly check user permission as expected. Authenticated but Unauthorized remote users could execute a Denial-of-Service (DoS) attack, execute arbitrary code, or obtain more privilege than intended on the machines. | 8.8 | 2.98% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24675 | In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process. | 9.8 | 1.15% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24676 | In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as. | 7.8 | 0.41% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24677 | Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirect the user somewhere else or download unwanted data. | 8.8 | 1.39% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24678 | An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges. | 8.8 | 1.45% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24679 | A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted. | 7.5 | 1.81% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24680 | In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database. | 7.0 | 0.26% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24683 | The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application. | 9.8 | 1.46% | 2020-12-22 | 2026-06-16 |
| CVE-2020-24685 | An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. Vulnerability allows attacker to stop the PLC. After stopping (ERR LED flashing red), physical access to the PLC is required in order to restart the application. This issue affects: ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions. | 8.6 | 1.61% | 2021-02-08 | 2026-06-16 |