| CVE | 摘要 | 来源 | 最高 CVSS | EPSS % | 公开时间 | 更新时间 |
|---|---|---|---|---|---|---|
| CVE-2024-58310 | APC Network Management Card 4 contains a path traversal vulnerability that allows unauthenticated attackers to access sensitive system files by manipulating URL parameters. Attackers can exploit directory traversal techniques to read critical system files like /etc/passwd by using encoded path traversal characters in HTTP requests. | [email protected] | 8.7 | 0.81% | 2025-12-11 | 2026-06-17 |
| CVE-2020-7526 | Improper Input Validation vulnerability exists in PowerChute Business Edition (software V9.0.x and earlier) which could cause remote code execution when a script is executed during a shutdown event. | [email protected] | 8.8 | 2.27% | 2020-08-31 | 2026-06-16 |
| CVE-2011-4263 | Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | [email protected] | 4.3 | 0.92% | 2011-12-07 | 2026-06-16 |
| CVE-2009-1798 | Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. NOTE: the login_username vector for Forms/login1 is already covered by CVE-2009-4406. | [email protected] | 4.3 | 1.99% | 2009-12-28 | 2026-06-16 |
| CVE-2009-1797 | Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to hijack the authentication of (1) administrator or (2) device users for requests that create new administrative users or have unspecified other impact. | [email protected] | 6.8 | 0.67% | 2009-12-28 | 2026-06-16 |
| CVE-2009-4406 | Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the login_username parameter. | [email protected] | 4.3 | 1.12% | 2009-12-23 | 2026-06-16 |
| CVE-2007-6226 | The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits. | [email protected] | 7.1 | 1.85% | 2007-12-04 | 2026-06-16 |
| CVE-2005-4326 | The web interface for American Power Conversion (APC) PowerChute Network Shutdown performs all communication in cleartext (base64-encoded), which allows remote attackers to sniff authentication credentials. | [email protected] | 5.0 | 1.47% | 2005-12-17 | 2026-06-16 |
| CVE-2004-2046 | Unknown vulnerability in APC PowerChute Business Edition 6.0 through 7.0.1 allows remote attackers to cause a denial of service via unknown attack vectors. | [email protected] | 5.0 | 2.61% | 2004-12-31 | 2026-06-16 |
| CVE-2004-0311 | American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attackers to gain unauthorized access. | [email protected] | 10.0 | 2.47% | 2004-11-23 | 2026-06-16 |
| CVE-2003-0099 | Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsprintf function. | [email protected] | 7.2 | 0.55% | 2003-03-03 | 2026-06-16 |
| CVE-2002-1924 | PowerChute plus 5.0.2 creates a "Pwrchute" directory during installation that is shared and world writeable, which could allow remote attackers to modify or create files in that directory. | [email protected] | 5.0 | 1.35% | 2002-12-31 | 2026-06-16 |
| CVE-2001-0564 | APC Web/SNMP Management Card prior to Firmware 310 only supports one telnet connection, which allows a remote attacker to create a denial of service via repeated failed logon attempts which temporarily locks the card. | [email protected] | 5.0 | 3.21% | 2001-08-22 | 2026-06-16 |
| CVE-2001-0040 | APC UPS daemon, apcupsd, saves its process ID in a world-writable file, which allows local users to kill an arbitrary process by specifying the target process ID in the apcupsd.pid file. | [email protected] | 2.1 | 0.86% | 2001-02-16 | 2026-06-16 |
| CVE-2000-1242 | The HTTP service in American Power Conversion (APC) PowerChute uses a default username and password, which allows remote attackers to gain system access. | [email protected] | 9.0 | 1.47% | 2000-12-31 | 2026-06-16 |