| CVE | 摘要 | 来源 | 最高 CVSS | EPSS % | 公开时间 | 更新时间 |
|---|---|---|---|---|---|---|
| CVE-2023-6926 | There is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access. | [email protected] | 8.4 | 0.53% | 2024-01-23 | 2026-06-17 |
| CVE-2023-38405 | On Crestron 3-Series Control Systems before 1.8001.0187, crafting and sending a specific BACnet packet can cause a crash. | [email protected] | 7.5 | 0.52% | 2023-07-17 | 2026-06-17 |
| CVE-2022-40298 | Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell. | [email protected] | 8.8 | 0.57% | 2022-09-22 | 2026-06-17 |
| CVE-2022-34102 | Insufficient access control vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can pause the uninstallation of an executable to gain a SYSTEM level command prompt. | [email protected] | 8.8 | 0.86% | 2022-09-13 | 2026-06-17 |
| CVE-2022-34101 | A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can place a malicious DLL in a certain path to execute code and preform a privilege escalation attack. | [email protected] | 7.8 | 0.33% | 2022-09-13 | 2026-06-17 |
| CVE-2022-34100 | A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation. | [email protected] | 8.8 | 1.02% | 2022-09-13 | 2026-06-17 |
| CVE-2022-23178 | An issue was discovered on Crestron HD-MD4X2-4K-E 1.0.0.2159 devices. When the administrative web interface of the HDMI switcher is accessed unauthenticated, user credentials are disclosed that are valid to authenticate to the web interface. Specifically, aj.html sends a JSON document with uname and upassword fields. | [email protected] | 9.8 | 75.71% | 2022-01-15 | 2026-06-17 |
| CVE-2020-16839 | On Crestron DM-NVX-DIR, DM-NVX-DIR80, and DM-NVX-ENT devices before the DM-XIO/1-0-3-802 patch, the password can be changed by sending an unauthenticated WebSocket request. | [email protected] | 7.5 | 1.18% | 2021-07-30 | 2026-06-16 |
| CVE-2019-18184 | Crestron DMC-STRO 1.0 devices allow remote command execution as root via shell metacharacters to the ping function. | [email protected] | 9.8 | 8.00% | 2019-11-27 | 2026-06-16 |
| CVE-2019-3939 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device. | [email protected] | 9.8 | 2.76% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3938 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords. | [email protected] | 7.8 | 0.26% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3937 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data. | [email protected] | 7.8 | 0.28% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3936 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow. | [email protected] | 7.5 | 2.14% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3935 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows. | [email protected] | 9.1 | 3.33% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3934 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code. | [email protected] | 5.3 | 7.73% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3933 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code. | [email protected] | 5.3 | 5.95% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3932 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge. | [email protected] | 9.8 | 36.33% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3931 | Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root. | [email protected] | 8.8 | 5.88% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3930 | The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A | [email protected] | 9.8 | 6.96% | 2019-04-30 | 2026-06-16 |
| CVE-2019-3929 KEV | The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remot | [email protected] | 9.8 | 98.95% | 2019-04-30 | 2026-06-16 |