schneider-electric interactive_graphical_scada_system_data_server CVE 漏洞(8)

CVE 數: 8 CPE versions: View versions table

摘要

本頁列出影響 schneider-electric interactive_graphical_scada_system_data_server 的已公開 CVE 漏洞(透過 NVD CPE 關聯)。每列包含嚴重程度評分、摘要與發布日期,便於識別與分析安全議題。

顯示 188 CVE 數
«« 第一頁 « 上一頁 第 1 / 1 頁 下一頁 »
CVE 摘要 來源 最高 CVSS EPSS % 公開時間 更新時間
CVE-2022-24317 A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 7.5 1.19% 2022-02-09 2026-06-17
CVE-2022-24316 A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 7.5 1.25% 2022-02-09 2026-06-17
CVE-2022-24315 A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 7.5 19.25% 2022-02-09 2026-06-17
CVE-2022-24314 A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 7.5 18.18% 2022-02-09 2026-06-17
CVE-2022-24313 A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 9.8 44.56% 2022-02-09 2026-06-17
CVE-2022-24312 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 9.8 3.46% 2022-02-09 2026-06-17
CVE-2022-24311 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 9.8 3.50% 2022-02-09 2026-06-17
CVE-2022-24310 A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) [email protected] 9.8 2.23% 2022-02-09 2026-06-17
«« 第一頁 « 上一頁 第 1 / 1 頁 下一頁 »
cvelogic Threat Intelligence