CVE 清單 – 發現高風險與在野利用漏洞

聚合 NVD、CVE 及多源情資,深度解析 RCE 等高危風險。系統整合 CVSS 與 EPSS 模型,動態追蹤 Exploit 資源與 PoC 公開狀態,研判可利用性。結合官方修補與修復方案,優化漏洞管理優先級,縮短回應週期,保障資產安全。

指派機構(CNA / 來源):[email protected] 移除此篩選

顯示 120279 筆結果
«« 第一頁 « 上一頁 第 1 / 14 頁 下一頁 »
CVE 描述 最高 CVSS EPSS % 公開時間 更新時間
CVE-2024-47784 Unverified Password Change for ANC software that allows an authenticated attacker to bypass the old Password check in the password change form via a web HMI This issue affects ANC software version 1.1.4 and earlier. 2.1 0.16% 2025-04-30 2026-06-17
CVE-2025-3449 A Generation of Predictable Numbers or Identifiers vulnerability in the SDM component of B&R Automation Runtime versions before 6.4 may allow an unauthenticated network-based attacker to take over already established sessions. 2.3 0.18% 2025-10-07 2026-06-17
CVE-2023-2876 Sensitive Cookie Without 'HttpOnly' Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1. 3.1 0.25% 2023-06-13 2026-06-17
CVE-2019-19092 ABB eSOMS versions 4.0 to 6.0.3 use ASP.NET Viewstate without Message Authentication Code (MAC). Alterations to Viewstate might thus not be noticed. 3.5 0.83% 2020-04-02 2026-06-16
CVE-2019-19090 For ABB eSOMS versions 4.0 to 6.0.2, the Secure Flag is not set in the HTTP response header. Unencrypted connections might access the cookie information, thus making it susceptible to eavesdropping. 3.5 0.52% 2020-04-02 2026-06-16
CVE-2019-18994 Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service. 3.9 0.60% 2019-12-18 2026-06-16
CVE-2025-13162 Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1. 4.1 0.08% 2026-06-23 2026-06-25
CVE-2020-11646 A log information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view log information reserved for other users. 4.3 1.00% 2020-10-15 2026-06-16
CVE-2019-19091 For ABB eSOMS versions 4.0 to 6.0.3, HTTPS responses contain comments with sensitive information about the application. An attacker might use this detail information to specifically craft the attack. 4.3 0.76% 2020-04-02 2026-06-16
CVE-2019-18997 The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access. 4.3 1.52% 2019-12-18 2026-06-16
CVE-2019-18995 The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting. 4.3 2.13% 2019-12-18 2026-06-16
CVE-2024-8036 ABB is aware of privately reported vulnerabilities in the product versions referenced in this CVE. An attacker could exploit these vulnerabilities by sending a specially crafted firmware or configuration to the system node, causing the node to stop, become inaccessible, or allowing the attacker to take control of the node. 4.6 0.14% 2024-10-25 2026-06-17
CVE-2024-13958 Stored Cross Site Scripting vulnerabilities exist in ASPECT if administrator creden-tials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. 4.6 0.15% 2025-05-22 2026-06-17
CVE-2022-1607 Cross-Site Request Forgery (CSRF) vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant allows Cross Site Request Forgery.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415. 4.6 0.21% 2023-02-24 2026-06-17
CVE-2026-0936 An Insertion of Sensitive Information into Log File vulnerability in B&R PVI client versions prior to 6.5 may be abused by an authenticated local attacker to gather credential information which is processed by the PVI client application. The logging function of the PVI client application is disabled by default and must be explicitly enabled by the user. 5.1 0.10% 2026-01-29 2026-06-17
CVE-2025-3448 Reflected cross-site scripting (XSS) vulnerabilities exist in System Diagnostics Manager (SDM) of B&R Automation Runtime versions before 6.4 that enables a remote attacker to execute arbitrary JavaScript code in the context of the attacked user’s browser session 5.1 0.25% 2025-10-07 2026-06-17
CVE-2024-6157 An attacker who successfully exploited these vulnerabilities could cause the robot to stop. A vulnerability exists in the PROFINET stack included in the RobotWare versions listed below.  This vulnerability arises under specific condition when specially crafted message is processed by the system. Below are reported vulnerabilities in the Robot Ware versions. * IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07 5.1 0.15% 2024-10-10 2026-06-17
CVE-2024-5624 Reflected Cross-Site Scripting (XSS) in Shift Logbook application of B&R APROL <= R 4.4-00P3 may allow a network-based attacker to execute arbitrary JavaScript code in the context of the user's browser session 5.1 0.24% 2024-08-29 2026-06-17
CVE-2024-13954 Serialized configuration information may be disclosed during device commissioning while using ASPECT's configuration toolsetThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. 5.1 0.18% 2025-05-22 2026-06-17
CVE-2024-12429 An attacker who successfully exploited these vulnerabilities could grant read access to files. A vulnerability exists in the AC500 V3 version mentioned. A successfully authenticated attacker can use this vulnerability to read system wide files and configuration All AC500 V3 products (PM5xxx) with firmware version earlier than 3.8.0 are affected by this vulnerability. 5.1 0.35% 2025-01-07 2026-06-17
«« 第一頁 « 上一頁 第 1 / 14 頁 下一頁 »