CVE-2023-31151 | Improper Certificate Validation

An Improper Certificate Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack. See SEL Service Bulletin dated 2022-11-15 for more details.

Published: 2023-05-10 Last update: 2026-06-17 Assigner: [email protected] Source: [email protected]

Conclusion & alert: CVE-2023-31151 is rated Low Risk (31.6/100): CVSS Medium severity, with low exploitation likelihood (EPSS 0.15%). Mandatory action: Monitor for updates and reassess as exploit intelligence or EPSS changes.

Risk is dynamic; we continuously reassess and refresh what is shown on this page as upstream context changes.

Exploit prediction scoring system (EPSS) score for CVE-2023-31151

EPSS lead: Daily EPSS estimates relative likelihood of exploitation; percentile ranks this CVE among scored vulnerabilities (higher = more severe relative rank).

# Date Old EPSS score New EPSS score Delta (New - Old)
1 2026-02-02 0.12% 0.15% +0.03%
2 2025-07-23 0.18% 0.12% -0.05%
3 2025-04-15 0.18%

Full EPSS history (5 records total)

Common vulnerability scoring system (CVSS) metrics for CVE-2023-31151

CVSS metrics for this CVE.

Base score Version Severity Vector Exploitability Impact Score source
4.7 3.1 MEDIUM
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:H)
Even with access, the exploit needs extra luck, timing, or a fussy environment to actually work.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:R)
A real person has to do something—click, install, enable—otherwise it doesn’t land.
Scope (S:C)
Breaking this can reach past the original component and bite other resources—bigger blast radius.
Confidentiality (C:L)
Some sensitive info could get out, but not a total data dump.
Integrity (I:L)
Attackers could change some data, but it’s limited—not everything goes.
Availability (A:N)
Service keeps running; no real outage angle.
1.6 2.7 [email protected]
4.2 3.1 MEDIUM
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N Click to expand
Attack vector (AV:N)
Could be attacked over the internet or any normal routed network—not just someone sitting at the machine.
Attack complexity (AC:H)
Even with access, the exploit needs extra luck, timing, or a fussy environment to actually work.
Privileges required (PR:N)
No account or special rights needed—anonymous or random user is enough.
User interaction (UI:R)
A real person has to do something—click, install, enable—otherwise it doesn’t land.
Scope (S:U)
Damage stays in the same “trust bubble” as the broken component—no big spill into unrelated systems.
Confidentiality (C:L)
Some sensitive info could get out, but not a total data dump.
Integrity (I:L)
Attackers could change some data, but it’s limited—not everything goes.
Availability (A:N)
Service keeps running; no real outage angle.
1.6 2.5 [email protected]

Weakness enumeration for CVE-2023-31151

Affected software / configurations for CVE-2023-31151

Vendor Product Version Raw CPE
selinc sel-2241_rtac_module_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-2241_rtac_module_firmware:*:*:*:*:*:*:*:*
selinc sel-3350_firmware >= r148-v0, < r150-v2 cpe:2.3:o:selinc:sel-3350_firmware:*:*:*:*:*:*:*:*
selinc sel-3505_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3505_firmware:*:*:*:*:*:*:*:*
selinc sel-3505-3_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3505-3_firmware:*:*:*:*:*:*:*:*
selinc sel-3530_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3530_firmware:*:*:*:*:*:*:*:*
selinc sel-3530-4_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3530-4_firmware:*:*:*:*:*:*:*:*
selinc sel-3532_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3532_firmware:*:*:*:*:*:*:*:*
selinc sel-3555_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3555_firmware:*:*:*:*:*:*:*:*
selinc sel-3560e_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3560e_firmware:*:*:*:*:*:*:*:*
selinc sel-3560s_firmware >= r147-v0, < r150-v2 cpe:2.3:o:selinc:sel-3560s_firmware:*:*:*:*:*:*:*:*

References for CVE-2023-31151

cvelogic Threat Intelligence