abbott 関連製品全体の CVE とセキュリティ脆弱性情報を集約し、CVSS、EPSS、公開日、脆弱性情報データを掲載しています。
公開された問題は vendor risk memory corruption に関連することが多く、vendor surface production workloads and vendor surface software deployment の文脈で vendor impact memory corruption and アプリケーションクラッシュ などの暴露リスクを伴う場合があります。
掲載データは公開脆弱性情報とセキュリティ公告に基づき、過去の暴露面と修補優先度の評価に利用できます。
| CVE | 概要 | ソース | CVSS 最大値 | EPSS(%) | 公開 | 更新 |
|---|---|---|---|---|---|---|
| CVE-2023-47262 | The startup process and device configurations of the Abbott ID NOW device, before v7.1, can be interrupted and/or modified via physical access to an internal serial port. Direct physical access is required to exploit. | [email protected] | 5.2 | 0.09% | 2023-11-14 | 2024-11-21 |
| CVE-2020-8997 | Older generation Abbott FreeStyle Libre sensors allow remote attackers within close proximity to enable write access to memory via a specific NFC unlock command. NOTE: The vulnerability is not present in the FreeStyle Libre 14-day in the U.S (announced in August 2018) and FreeStyle Libre 2 outside the U.S (announced in October 2018). | [email protected] | 8.8 | 0.56% | 2020-02-16 | 2024-11-21 |
| CVE-2017-12716 | Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | [email protected] | 6.5 | 0.04% | 2018-04-25 | 2024-11-21 |
| CVE-2017-12714 | Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | [email protected] | 6.5 | 0.25% | 2018-04-25 | 2024-11-21 |
| CVE-2017-12712 | The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | [email protected] | 8.8 | 0.38% | 2018-04-25 | 2024-11-21 |
| CVE-2017-5149 | An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 (RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability). The identities of the endpoints for the communication channel between the transmitter and St. Jude Medical's web site, Merlin.net, are not verified. This may allow a man-in-the-middle attacker to access or influence communications between the identified endpoints. | [email protected] | 8.9 | 0.32% | 2017-02-13 | 2026-05-13 |