汇总 abbott 相关全部产品的 CVE 与安全漏洞情报,包括 CVSS、EPSS、公开时间与漏洞情报数据。
已披露问题常与 内存损坏 相关,可能在 生产负载与软件部署 场景中带来 内存损坏与应用崩溃 等暴露风险。
相关漏洞数据主要来源于公开漏洞披露与安全公告,可用于评估历史漏洞暴露面与修复优先级。
| CVE | 摘要 | 来源 | 最高 CVSS | EPSS % | 公开时间 | 更新时间 |
|---|---|---|---|---|---|---|
| CVE-2023-47262 | The startup process and device configurations of the Abbott ID NOW device, before v7.1, can be interrupted and/or modified via physical access to an internal serial port. Direct physical access is required to exploit. | [email protected] | 5.2 | 0.09% | 2023-11-14 | 2024-11-21 |
| CVE-2020-8997 | Older generation Abbott FreeStyle Libre sensors allow remote attackers within close proximity to enable write access to memory via a specific NFC unlock command. NOTE: The vulnerability is not present in the FreeStyle Libre 14-day in the U.S (announced in August 2018) and FreeStyle Libre 2 outside the U.S (announced in October 2018). | [email protected] | 8.8 | 0.56% | 2020-02-16 | 2024-11-21 |
| CVE-2017-12716 | Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | [email protected] | 6.5 | 0.04% | 2018-04-25 | 2024-11-21 |
| CVE-2017-12714 | Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | [email protected] | 6.5 | 0.25% | 2018-04-25 | 2024-11-21 |
| CVE-2017-12712 | The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | [email protected] | 8.8 | 0.38% | 2018-04-25 | 2024-11-21 |
| CVE-2017-5149 | An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 (RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability). The identities of the endpoints for the communication channel between the transmitter and St. Jude Medical's web site, Merlin.net, are not verified. This may allow a man-in-the-middle attacker to access or influence communications between the identified endpoints. | [email protected] | 8.9 | 0.32% | 2017-02-13 | 2026-05-13 |