bender 関連製品全体の CVE とセキュリティ脆弱性情報を集約し、CVSS、EPSS、公開日、脆弱性情報データを掲載しています。
一般的な弱点パターンには vendor risk cross-site scripting、パス処理の欠陥、バッファオーバーフロー, and vendor risk memory corruption があり、vendor surface production workloads の利用場面で vendor impact memory corruption、ファイル上書き, and vendor impact session compromise などのリスクが生じる可能性があります。
掲載データは公開脆弱性情報とセキュリティ公告に基づき、過去の暴露面と修補優先度の評価に利用できます。
| CVE | 概要 | ソース | CVSS 最大値 | EPSS(%) | 公開 | 更新 |
|---|---|---|---|---|---|---|
| CVE-2021-34602 | In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges. | [email protected] | 8.8 | 1.35% | 2022-04-27 | 2024-11-21 |
| CVE-2021-34601 | In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI. | [email protected] | 9.8 | 0.99% | 2022-04-27 | 2024-11-21 |
| CVE-2021-34592 | In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields. | [email protected] | 8.8 | 1.35% | 2022-04-27 | 2024-11-21 |
| CVE-2021-34591 | In Bender/ebee Charge Controllers in multiple versions are prone to Local privilege Escalation. An authenticated attacker could get root access via the suid applications socat, ip udhcpc and ifplugd. | [email protected] | 7.8 | 0.22% | 2022-04-27 | 2024-11-21 |
| CVE-2021-34590 | In Bender/ebee Charge Controllers in multiple versions are prone to Cross-site Scripting. An authenticated attacker could write HTML Code into configuration values. These values are not properly escaped when displayed. | [email protected] | 5.4 | 0.41% | 2022-04-27 | 2024-11-21 |
| CVE-2021-34589 | In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface. | [email protected] | 7.5 | 0.91% | 2022-04-27 | 2024-11-21 |
| CVE-2021-34588 | In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty after reboot . | [email protected] | 8.6 | 0.83% | 2022-04-27 | 2024-11-21 |
| CVE-2021-34587 | In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable. | [email protected] | 5.3 | 0.84% | 2022-04-27 | 2024-11-21 |
| CVE-2019-19885 | In Bender COMTRAXX, user authorization is validated for most, but not all, routes in the system. A user with knowledge about the routes can read and write configuration data without prior authorization. This affects COM465IP, COM465DP, COM465ID, CP700, CP907, and CP915 devices before 4.2.0. | [email protected] | 9.1 | 0.99% | 2020-10-16 | 2024-11-21 |