bender 漏洞與 CVE 列表(9)

產品(CPE): — CVE 數: 9

bender 漏洞概覽

彙總 bender 相關全部產品的 CVE 與安全漏洞情報,包括 CVSS、EPSS、公開時間與漏洞情報資料。

常見弱點模式包括 跨站腳本、路徑處理缺陷、緩衝區溢位與記憶體損壞,在 生產負載與軟體部署 使用場景中可能帶來 記憶體損壞、檔案覆寫與工作階段劫持 等風險。

相關漏洞資料主要來源於公開漏洞披露與安全公告,可用於評估歷史漏洞暴露面與修補優先順序。

漏洞分布趨勢(近 24 個月)

顯示 199 CVE 數
«« 第一頁 « 上一頁 第 1 / 1 頁 下一頁 »
CVE 摘要 來源 最高 CVSS EPSS % 公開時間 更新時間
CVE-2021-34602 In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges. [email protected] 8.8 3.44% 2022-04-27 2024-11-21
CVE-2021-34601 In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI. [email protected] 9.8 0.42% 2022-04-27 2024-11-21
CVE-2021-34592 In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields. [email protected] 8.8 3.03% 2022-04-27 2024-11-21
CVE-2021-34591 In Bender/ebee Charge Controllers in multiple versions are prone to Local privilege Escalation. An authenticated attacker could get root access via the suid applications socat, ip udhcpc and ifplugd. [email protected] 7.8 0.13% 2022-04-27 2024-11-21
CVE-2021-34590 In Bender/ebee Charge Controllers in multiple versions are prone to Cross-site Scripting. An authenticated attacker could write HTML Code into configuration values. These values are not properly escaped when displayed. [email protected] 5.4 0.35% 2022-04-27 2024-11-21
CVE-2021-34589 In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface. [email protected] 7.5 0.30% 2022-04-27 2024-11-21
CVE-2021-34588 In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty after reboot . [email protected] 8.6 0.26% 2022-04-27 2024-11-21
CVE-2021-34587 In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable. [email protected] 5.3 0.29% 2022-04-27 2024-11-21
CVE-2019-19885 In Bender COMTRAXX, user authorization is validated for most, but not all, routes in the system. A user with knowledge about the routes can read and write configuration data without prior authorization. This affects COM465IP, COM465DP, COM465ID, CP700, CP907, and CP915 devices before 4.2.0. [email protected] 9.1 0.26% 2020-10-16 2024-11-21
«« 第一頁 « 上一頁 第 1 / 1 頁 下一頁 »